GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
RG-S5750V2-48GT4XS-L
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

48¿ÚǧÕ×µçÈý²ãÍø¹ÜÐÍÖ÷Ìâ»ã¾ÛÒÔÌ«Íø»¥»»»ú£¬ÍòÕ×ÉÏÐУ¬RG-S5750V2-48GT4XS-L

ÓÃÓÚÖÐÓ×ÐÍÍøÂç»ã¾ÛÒÔ¼°Ö÷Ì⻥»»»ú£¬4¸öÍòÕ×ÉÏÐйâ¿Ú

²úÆ·¸öÐÔ£º

  • ¶Ë¿Ú·á˶£¬¿ìÂÊÉý¼¶£¬48¸öǧÕ×ÒÔÌ«Íø¿Ú£¬4¸ö10G¹â¿ÚÓÃÓÚÉÏÁª
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬½Ã½Ý×éÍø»úÄÜÇ¿
  • Èý²ã·ÓɺÍ̸°Ñ¿Ø£¬ÊÊÅä¶à³ÁÒµÎñ£¬ÐÅÏ¢´«Êä¸ßЧÓб£ÏÕ
  • ÍøÂ簲ȫʵʱ¼à²â£¬Ö§³ÖCPP¡¢NFPP¡¢RLDP£¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ
  • ÃÀÂúµÄQoSÕ½Êõ£¬½Ã½Ý·ÖÅäÍøÂç×ÊÔ´£¬¿ìÂʲ»±ä²»Óµ¼·
  • Ö§³ÖSNMP¡¢RMON¡¢Syslog¡¢USB¸öÐÔ¼°CLI¡¢WebÍø¹Ü¡¢TelnetµÈ¶à³ÁÖÎÀí·½Ê½£¬Ò×ÊØ»¤
µ±¼´Õ÷ѯ
Èý²ãǧÕ×Ö÷Ìâ&»ã¾Û»¥»»»ú RG-S5750V2-48GT4XS-L
¿ÉÓÃÓÚÖÐÓ×ÐÍÔ°ÇøÍøÂç»ã¾ÛÉ豸£¬Õ¼ÓÐ48¸öǧÕ××ÔÊÊÓ¦ÒÔÌ«Íø¿Ú£¬4¸öÍòÕ×ÉÏÐйâ¿Ú£¬¶Ë¿Ú·á˶£¬¿ìÂÊÉý¼¶
¿ÉÓÃÓÚÖÐÓׯóÒµÖ÷ÌâÉ豸£¬Ìṩ¸ß¿¿µÃסÐÔ£¬¸ßЧÐÔ£¬ÈßÓàÐÔ£¬¿ÉÖÎÀíÐԵȣ¬¸ÄÉÆÍøÂç»úÄÜ
Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬½Ã½Ý×éÍø»úÄÜÇ¿
ºÁÃë¼¶¹ÊÕϸ´Ô­
¸ßÀ©´ó
¼ò»¯×éÍø
VSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓÈçÓö¹ÊÕÏ£¬¿ÉºÁÃë¼¶Çл»Á´Â·£¬±£ÕÏÍøÂç²»¼ä¶Ï
Èý²ã·ÓÉÖ°ÄܰѿØ£¬ÊÊÅä¶à³ÁÒµÎñ£¬ÐÅÏ¢´«Êä¸ßЧÓб£ÏÕ
IPV4¡¢IPV6ºÍ̸
·á˶µÄ×é²¥ºÍ̸
¾²Ì¬¡¢¶¯Ì¬Â·ÓÉ
Ó²¼þÖ§³ÖË«ºÍ̸ջÐÅÏ¢¸ß¿ì»¥»»£¬Âú×ã´ÓÔ°ÇøIPV4µ½IPV6µÄÍøÂç¹ý¶É£¬µØÖ·ÈÝÁ¿ÓëÍøÂ簲ȫ´ó´óÌáÉý
¶àÖÖÍøÂ簲ȫսÊõ£¬ÊµÊ±¼à²â£¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ
CPP±£»¤Õ½Êõ
NFPP±£»¤Õ½Êõ
´óÁ¿¡¢ÔÓÂÒÊý¾ÝÏȾ­¹ýCPP´¦Öã¬Ô¤·ÀÖ±½Ó¹¥»÷µ½CPU£¬±£ÕÏCPU¸ßÔËÐÐϵIJ»±äÐÔ£¬ÓÐЧÌá¸ßÉ豸µÄ°²È«»úÄÜ
ÃÀÂúµÄQoSÕ½Êõ£¬ÊµÏÖÍøÂç×ÊÔ´½Ã½Ý·ÖÅ䣬¿ìÂʲ»±ä²»Óµ¼·
¾ß±¸MACÁ÷¡¢IPÁ÷¡¢ÀûÓÃÁ÷µÈ¶à²ãÁ÷·ÖÀàºÍÁ÷½ÚÔìÄÜÁ¦
±£Õ϶àÒµÎñÁ÷Á¿¾«×¼·ÖÅ䣬ʵÏÖÓÃÍø²»Óµ¼·£¬Ìṩ¸ßÖÊÁ¿ÍøÂç
¶à³ÁÍøÂçÖÎÀí·½Ê½ ʵÏÖµ¥Ò»ÇáËɵÄÍøÂçÊØ»¤
ÖÎÀí¸öÐÔ
ÖÎÀí·½Ê½
¶ą̀É豸ÖÎÀí
Ö§³ÖRMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾¸öÐÔ£¬±£ÏÕÈÕ³£ÓÃÍøµÄÕý³£Õï¶ÏÓëÊØ»¤

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

ϵͳ¹æ¸ñ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
»¥»»ÈÝÁ¿ 1.28Tbps/12.8Tbps 1.28Tbps/12.8Tbps 1.28Tbps/12.8Tbps
°üת·¢ÂÊ 228Mpps 228Mpps 264Mpps
POE¹©µç³ß¶È ²»Ö§³Ö
ÎÂ¶È¼à¿Ø ÎÂ¶È¼à¿Ø£ºÖ§³Ö
ζȸ澯£ºÖ§³Ö
¹ýα£»¤£º²»Ö§³Ö
µçÉÈ¼à¿Ø ¹ÊÕϸ澯£ºÖ§³Ö
ÊÖ¶¯µ÷¿ì£º²»Ö§³Ö
ÖÇÄܵ÷¿ì£ºÖ§³Ö
µçÔ´¼à¿Ø Ä£¿é¼à¿Ø£º²»Ö§³Ö
¹ÊÕϸ澯£ºÖ§³Ö
ÖÇÄÜÉϵ磺²»Ö§³Ö

½Ó¿ÚÓë²å²Û

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
¹Ì»¯ÒµÎñ½Ó¿Ú 28¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú£¨º¬4¸ö100/1000M SFP¹âµç¸´Óýӿڣ©
4¸ö1G/10G SFP+½Ó¿Ú
28¸ö100/1000M SFP½Ó¿Ú£¨º¬8¸ö10/100/1000Base-T¹âµç¸´Óýӿڣ©
4¸ö1G/10G SFP+½Ó¿Ú
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1G/10G SFP+½Ó¿Ú
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öRJ45µÄMGMT½Ó¿Ú
1¸öUSB 2.0½Ó¿Ú
1¸öRJ45 Console½Ó¿Ú
1¸öRJ45µÄMGMT½Ó¿Ú
1¸öUSB 2.0½Ó¿Ú
1¸öRJ45 Console½Ó¿Ú
1¸öRJ45µÄMGMT½Ó¿Ú
1¸öUSB 2.0½Ó¿Ú
1¸öRJ45 Console½Ó¿Ú
µçÔ´Ä£¿é²å²Û 2 2 2
µçÔ´Ä£¿éÐͺŠRG-PA70I
RG-PD70I
RG-PA70I
RG-PD70I
RG-PA70I
RG-PD70I
¹Ì»¯µçÉÈÊýÁ¿ 3 3 2

³ß´çÓë³ÁÁ¿

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
²úÆ·³ß´ç
£¨¿í×Éî׸ߣ©
440mm x 280mm x 44mm 440mm x 300mm x 44mm 440mm x 300mm x 44mm
³ÁÁ¿ 3.9kg 4.2kg 4.2kg
»ú¼Ü³ß´ç 1RU 1RU 1RU
×°Ö÷½Ê½ ×ÀÃæ/±Ú¹Ò/»ú¼Ü£¨¹ñ£©

µçÔ´Ó빦ºÄ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
¶î¶¨ÊäÈëµçѹ RG-PA70I£º100V AC~240V AC£¬50~60Hz
RG-PD70I£º192V DC~288V DC
×î´óÊäÈëµçѹÁìÓò RG-PA70I£º90V AC~264V AC£¬50~60Hz
¶î¶¨ÊäÈëµçÁ÷ 2A
µçÔ´ÈßÓ౸·Ý 1+1
Õû»ú×î´ó¹¦ºÄ 45W£¨²»º¬À©´ó¿¨£© 55W£¨²»º¬À©´ó¿¨£© 55W£¨²»º¬À©´ó¿¨£©

»·¾³Óë¿¿µÃסÐÔ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
µçÔ´ÈȲå°Î Ö§³Ö
ÏßÀÂÈȲå°Î Console¿Ú¡¢USB¿Ú¡¢ÒµÎñ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ¹¤×÷ζȣº0°C~45°C
´æ´¢Î¶ȣº-40°C~70°C º£°Î3000~5000m£ºº£°ÎÿÉý¸ß220m£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ ¡£
ʪ¶È ¹¤×÷ʪ¶È£º10%RH~90%RH£¨ÎÞÄý¹Ì£©
´æ´¢Êª¶È£º5%RH~95%RH£¨ÎÞÄý¹Ì£©
ÔëÉù £¼78dBA
É¢ÈÈ ·çÀäÉ¢ÈÈ£¬×ó½øÓÒ³ö

Èí¼þ¹æ¸ñ

²úÆ·ÐͺŠRG-S5750V2-28GT4XS-L RG-S5750V2-28SFP4XS-L RG-S5750V2-48GT4XS-L
VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖIP subnet-based VLAN
Ö§³ÖGVRP
Ö§³ÖÕ½ÊõVLAN
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
Á´Â·¾ÛºÏ Ö§³ÖLACP(802.3ad)
¶Ë¿Ú¾µÏñ Ö§³ÖÒ»¶ÔÒ»¾µÏñ
Ö§³Ö»ùÓÚÁ÷µÄ¾µÏñ
ÌìÉúÊ÷ Ö§³ÖSTP¡¢RSTP¡¢MSTP
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
IPv6»ù´¡ºÍ̸ IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢ND-Snooping¡¢ICMPv6¡¢ÎÞ״̬×Ô¶¯ÅäÖá¢Path MTU Discovery
IP·ÓÉ Ö§³Ö¾²Ì¬Â·ÓÉ
Ö§³ÖRIP£¬RIPng
Ö§³ÖOSPFv2£¬OSPFv3£¬IS-ISv4£¬IS-ISv6
Ö§³ÖBGP4£¬BGP4+
Ö§³ÖµÈ¼Û·ÓÉ
Ö§³Ö»ùÓÚ°üµÄ¸ºÔØÆ½ºâºÍ»ùÓÚÁ÷µÄ¸ºÔØÆ½ºâ
×é²¥ Ö§³ÖIGMP v1£¬v2£¬v3£¬IGMP ´úÀí
Ö§³ÖIGMP v1£¬v2ºÍv3 Snooping
Ö§³ÖIGMP ¹ýÂË£¬ IGMP¼±¾çÍÑÀë
Ö§³ÖPIM-DM£¬PIM-SM£¬PIM-SSM
Ö§³ÖMLD Snooping£¬MLD
Ö§³ÖPIM for IPv6
Ö§³ÖMSDP
ACL Ö§³Ö½Ã½Ý¶àÑùµÄÓ²¼þACL£º
Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³Öר¼Ò¼¶ACL£¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È
°²È«¸öÐÔ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞ¿ì
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON(1,2,3,9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢SNMP over IPv6¡¢IPv6 MIB support for SNMP ¡¢SSHv6¡¢Telnet v6¡¢FTP/TFTP v6¡¢DNS v6¡¢NTP for v6¡¢Traceroute v6¡¢MACCŵ¿Í¹«ÓÐÔÆÆ½Ì¨ÖÎÀí
¸ß¿¿µÃסÐÔ Ö§³ÖVSU£¨Ðé¹¹»¯¼¼Êõ£¬½«¶ą̀É豸Ðé×é³É1̨£©¡¢Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓɺÍ̸¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖERPS£¨G.8032£©¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢µçÔ´Ä£¿éÖ§³ÖÈȲå°ÎÖ°ÄÜ
EEE Ö§³ÖIEEE 802.3az³ß¶ÈµÄEEE£¨Energy Efficient Ethernet£¬½ÚÄÜÒÔÌ«Íø£©¼¼Êõ

·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

ÍòÕ×Á´Â·
ǧÕ×Á´Â·
ÍÆ¼öÓÃÓÚÖÐÓ×ÐÍÆóÒµÔ°ÇøÍø£¬½ÌÓýÐ£Ô°Íø/³ÇÓòÍø£¬¿í´øÓ×ÇøÍøÂçµÈ»ã¾ÛÉ豸£¬ÊµÏÖÍòÕ×»ã¾Ûµ½Ö÷ÌâµÄ¸ß»úÄÜ´ø¿íÁ´Â·£¬Âú×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔö³¤µÄ±ØÒª
match1
RG-S5750V2-L»ã¾Û»¥»»»ú
RG-S2910-L½ÓÈ뻥»»»ú
ÍÆ¼öÓÃÓÚÖÐÓׯóÒµÔ°ÇøÍøÖ÷ÌâÉ豸£¬Í¨¹ý1+1µçÔ´ÈßÓ࣬ÌáÉýÓ²¼þ¿¿µÃסÐÔ£¬Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬´ó·ùÌáÉýÍøÂçϵͳµÄ¿¿µÃסÐԺ͸ßЧÐÔ
match2
ÄÚ²¿·þÎñÆ÷
RG-S5750V2-L»ã¾Û»¥»»»ú
RG-S2910-L½ÓÈ뻥»»»ú
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÀûÓð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
µçÔ´(6)
É¢ÈÈ(4)
¶Ë¿Ú(4)
ºÏÓó¡¾°(1)
·ÓÉÖ°ÄÜ(4)
»·Â·¼ì²â(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S5750V2-28GT4XS-LÊÇ·ñÓзÓÉÖ°ÄÜ£¿
ÓÐЧ 32 ÎÞÓà 6

É豸ÊôÓÚÈý²ãÖ÷Ìâ»ã¾Û»¥»»»ú£¬ÓµÓÐÈý²ã·ÓɺÍ̸¸öÐÔ£¬Ö§³ÖIPv4/IPv6Ë«ºÍ̸ջ¶à²ã»¥»»£»Ö§³ÖÌìÉúÊ÷ºÍ̸802.1D¡¢802.1w¡¢802.1s£¬±£Õϼ±¾çÊÕÁ²£»²¢Ö§³ÖIGMP Snooping¡¢IGMPµÈ·á˶×é²¥ºÍ̸£¬ÒÔ¼°¾²Ì¬Â·ÓÉÓëRIP¡¢BGP4µÈ¶¯Ì¬Â·ÓÉ£¬Ìá¸ßÍøÂç»úÄÜ ¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S5750V2-28SFP4XS-LÓÐÍòÕ×¹â¿ÚÂð£¿
ÓÐЧ 31 ÎÞÓà 5

ÓеÄ£¬É豸ռÓÐ28¸öSFP¹â¿Ú£¬8¸ö¸´ÓõÄ10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú£¬¶Ë¿ÚÊýÁ¿ÌáÉý£¬Ìṩ½Ã½ÝÍøÂ粿Êð ¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ ¡£©£¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ ¡£©£¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À ¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿