GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
RG-S2910V2-24GT4SFP-L
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

24¿ÚǧÕ×Èý²ãÍø¹ÜÐͺÐʽ½ÓÈ뻥»»»ú £¬Ç§Õ×ÉÏÐÐ £¬RG-S2910V2-24GT4SFP-L

ÎªÔ°ÇøÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæµÄÀûÓÃ

²úÆ·¸öÐÔ£º

  • 24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø¿Ú £¬4¸ö¶ÀÁ¢Ç§Õ×SFP¹â¿Ú
  • ÌØÓеÄCPU±£»¤Õ½Êõ £¬É豸²»±ä¸ß¿¿µÃס £¬ÍøÂçÔËÐв»¼ä¶Ï
  • ¼±¾ç»·Â·¼ì²â£¨RLDP£© £¬ÍøÂ簲ȫ¸üÁ÷³©
  • Ö§³ÖEEE¼¼Êõ £¬×Ô¶¯µ÷½Ú¶Ë¿Ú¹¦ÂÊ £¬½µÔëÇÒ½ÚÄÜ
  • ¶à·½Ê½Íø¹Ü £¬É豸ÖÎÀíÇáËÉÒײÙ×÷
µ±¼´Õ÷ѯ

Èí¼þºÍ̸

gaokekao
¸ß¿¿µÃסÐÔ
STP/RSTP/MSTP
RLDP/LLDP
LACP
yinyongxieyi
ÀûÓúÍ̸
DNS
DHCP Server
Port based VLAN¡¢MAC Based VLAN¡¢GVRP
REUP
IGMP SNOOPING
guanlitexing
ÖÎÀí¸öÐÔ
SNMP
RMON
Syslog/Debug
NTP/SNTP
WebÖÎÀí¡¢CLI(Telnet/Console)¡¢SSH
anquantexing
°²È«¸öÐÔ
CPP
ACL/QoS
DOS PROTECTION
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
¿ÚÁȫ

24¿ÚǧÕ×Èý²ãÍø¹ÜÐͽÓÈ뻥»»»ú
RG-S2910V2-24GT4SFP-L

ÎªÔ°ÇøÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæµÄÀûÓà £¬Í¬Ê±ÌṩǧÕ×ÉÏÐдø¿í
Âú×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔö³¤µÄ±ØÒª

ÌØÓеÄCPU±£»¤Õ½Êõ £¬É豸²»±ä¿¿µÃס £¬ÍøÂçÔËÐв»¼ä¶Ï

ÓµÓÐCPP¸öÐÔ£¨CPU Protect Policy£© £¬½ÚÔì·¢ÍùCPUµÄ±¨ÎÄÀàÐͺÍÁ÷Á¿´óÓ× £¬È·±£Õý³£ºÍ̸±¨ÎĺÍÖÎÀí±¨ÎĵÄ
´¦Öà £¬³ä·Ö±£»¤CPU²»±»·¸·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´¿÷Ëð

¼±¾ç»·Â·¼ì²â£¨RLDP£© £¬ÍøÂ簲ȫ¸üÁ÷³©

Ö§³Ö¼±¾çÁ´Â·¼ì²âºÍ̸£¨RLDP£© £¬¼±¾ç·¢ÏÖ¶Ë¿Ú˽½ÓHubµÈÉ豸ÐγɵĻ·Â· £¬²¢ÊµÊ±×÷³öÖÒ¸æÍ¨Öª¡¢¹Ø¹Ø¶Ë¿ÚµÈ´¦ÖÃ
´Ó¶øÔ¤·ÀÓÉÓÚ»·Â·Ôì³ÉµÄ¹ã²¥·ç±© £¬±£ÏÕÉ豸ºÍÁ´Â·°²È«

Ö§³ÖEEE¼¼Êõ £¬×Ô¶¯µ÷½Ú¶Ë¿Ú¹¦ÂÊ £¬½µÔëÇÒ½ÚÄÜ

Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©¼¼Êõ £¬¶Ë¿ÚÁ÷Á¿½ÏÓ×ʱ £¬¹¦ÂÊ×Ô¶¯½µµÍ £¬½Ú¼óÉ豸ÄܺÄ£»¶Ë¿ÚÎÞÁ÷Á¿Ê± £¬×Ô¶¯½øÈëÐÝÃßģʽ £¬½µÔëÇÒ½ÚÄÜ

¶à·½Ê½Íø¹Ü £¬É豸ÖÎÀíÇáËÉÒײÙ×÷

µ¥Ì¨É豸ÖÎÀí
¶ą̀É豸ÖÎÀí

¿ÉѡȡWebÖÎÀí¡¢CLI(ºÅÁîÐнӿÚ)µÈ¶àÑù»¯µÄ±¾µØ»¯ÖÎÀíºÍÊØ»¤·½Ê½ £¬É豸ÖÎÀíµ¥Ò»±ã½Ý

¼¼Êõ²ÎÊý

¼¼Êõ²ÎÊý

²ÎÊýÃèÊö

²úÆ·ÐͺÅ

RG-S2910V2-24GT4SFP-L

RG-S2910V2-24GT4XS-L

RG-S2910V2-48GT4SFP-L

RG-S2910V2-48GT4XS-L

RG-S2910V2-24GT4SFP-P-L

RG-S2910V2-24GT4XS-P-L

¹Ì¶¨¶Ë¿Ú

24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö1G SFP¹â¿Ú £¬¹Ì»¯µ¥»¥»»µçÔ´

 

24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö10G/1G SFP+¹â¿Ú £¬¹Ì»¯µ¥»¥»»µçÔ´

48¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö1G SFP¹â¿Ú £¬¹Ì»¯µ¥»¥»»µçÔ´

 

48¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö10G/1G SFP+¹â¿Ú £¬¹Ì»¯µ¥»¥»»µçÔ´

24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö1G SFP¹â¿Ú £¬¹Ì»¯µ¥»¥»»µçÔ´

 

24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö10G/1G SFP+¹â¿Ú £¬¹Ì»¯µ¥»¥»»µçÔ´

 

24¸öµç¿ÚÖ§³ÖPoEºÍPoE+¹©µç£»Õû»ú×î´óPoE/PoE+Êä³ö¹¦ÂÊ£º370W

»¥»»ÈÝÁ¿

336Gbps/3.36Tbps

432Gbps/4.32Tbps

336Gbps/3.36Tbps

°üת·¢ÂÊ

51Mpps/126Mpps

108Mpps/126Mpps

87Mpps/166Mpps

144Mpps/166Mpps

51Mpps/126Mpps

108Mpps/126Mpps

PoE

²»Ö§³Ö

²»Ö§³Ö

¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©

Ö§³Ö×Ô¶¯¡¢½ÚÄÜ¡¢¾²Ì¬¹©µçÖÎÀíģʽ

Ö§³Ö¶Ë¿ÚÓÅÏȼ¶

MACµØÖ·±í

Ö§³Ö¾²Ì¬MACµØÖ·

Ö§³ÖMACµØÖ·¹ýÂË

802.1Q VLAN

Ö§³Ö4K 802.1Q VLAN

Ö§³ÖPort based VLAN

Ö§³ÖMAC based VLAN

Ö§³ÖProtocol based VLAN

Ö§³ÖGVRP

¶þ²ã»·Íø¼¼Êõ

Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS £¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·ÃÀÂú¼æÈÝ

¶Ë¿Ú¾ÛºÏ

Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½

Ö§³ÖLACP¶¯Ì¬¾ÛºÏ

Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½Ê½¿ÉÅäÖÃ

DHCP

Ö§³ÖDHCP Server

Ö§³ÖDHCP Client

Ö§³ÖDHCP Snooping

Ö§³ÖDHCP Relay

IP·ÓÉ

¾²Ì¬Â·ÓÉ¡¢RIP¡¢RIPng¡¢OSPFv2¡¢IPv6

ACL

Ö§³Ö³ß¶ÈIP ACL

Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©

Ö§³ÖMACÀ©´óACL

Ö§³ÖACL80

Ö§³ÖÈ«¾ÖACL

Ö§³ÖACL³Á¶¨Ïò

QoS

Ö§³Ö¶Ë¿ÚÏÞ¿ì

Ö§³Ö802.1p/DSCPÁ÷Á¿·ÖÀà

ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ

Ö§³ÖSP¡¢WRR¡¢SP+WFQ¡¢SP+WRR¡¢RED/WRED¶ÓÁе÷¶È

°²È«¸öÐÔ

¹ýÂË·¸·¨µÄMACµØÖ·

Ö§³Ö¹ã²¥·ç±©¡¢¶à²¥·ç±©¡¢Î´³ÛÃûµ¥²¥ÒÖÔì

Ö§³ÖSSH

Ö§³ÖCPP

EEE

Ö§³ÖIEEE 802.3az ³ß¶ÈµÄ EEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ £¬´Ó¶ø´ó·ù¶ÈµÄ¼õÓ×¶Ë¿ÚÔڸý׶εŦºÄ £¬´ïµ½Á˽ÚÄܵÄÖ÷ÕÅ¡£

ÖÎÀí¸öÐÔ

SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web

µçÔ´

»¥»»£¨AC£©ÊäÈ룺
¶î¶¨µçѹÁìÓò£º100V~240V
×î´óµçѹÁìÓò£º90V~264V
ƵÂÊ£º50/60Hz

µçÉÈ

Ö§³ÖµçÉȵ÷¿ì

¹¦ºÄ

≤28W

≤46W

Õû»ú¹¦ºÄ£¨²»´øPOE¸ºÔØ£©<42W

Õû»ú¹¦ºÄ£¨PoEÂúÔØ£©<432W

MTBF

£¾200K

ζÈ

¹¤×÷ζȣº0¡æ~50¡æ

´æ´¢Î¶ȣº-40¡æ~70¡æ

ʪ¶È

¹¤×÷ʪ¶È£º10%~90%RH£¨ÎÞÀäÄý£©

´æ´¢Êª¶È£º5%~95%RH£¨ÎÞÀäÄý£©

¶Ë¿Ú·ÀÀ×
6KV

·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

ÍòÕ×ÍøÂç
ǧÕ×ÍøÂç
match
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
¶Ë¿ÚÐÝÃß(1)
PoE¹©µç(3)
µçÔ´(1)
½ÚÄÜ(1)
»·Íø»¥»»»ú(1)
¹âÄ £¿é(1)
ºÏÓó¡¾°(2)
¹¦ÂÊ(2)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S2910V2-LϵÁо«¼òÐÍǧÕ×»¥»»»úÊÇ·ñÊÇ»·Íø»¥»»»ú £¿
ÓÐЧ 53 ÎÞÓà 8

ÊǵÄ £¬ÎÒ˾֧³Ö“ERPSºÍ̸”µÄ»¥»»»ú¶¼ÊÇ»·Íø»¥»»»ú £¬ÏêÇéÒ³Ãæ¼¼Êõ²ÎÊý°å¿éÒ²Äܹ»²éµ½´ËÐÅÏ¢¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S2910V2-LϵÁо«¼òÐÍǧÕ×»¥»»»úÖÐÓÐÖ§³ÖPoE¹©µçµÄÂ𠣿
ÓÐЧ 41 ÎÞÓà 8

RG-S2910V2-24GT4SFP-P-L¡¢RG-S2910V2-24GT4XS-P-LÕâÁ½¿î24¸öµç¿ÚÖ§³ÖPoEºÍPoE+¹©µç£»Õû»ú×î´óPoE/PoE+Êä³ö¹¦ÂÊ£º370W £¬¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ £¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖà £¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ £¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Òé £¿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌâ £¬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿