RG-S2910-48GT4SFP-L
RG-S2910-48GT4SFP-L
RG-S2910-48GT4SFP-L
RG-S2910-48GT4SFP-L
RG-S2910-48GT4SFP-L
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

RG-S2910-LϵÁÐ48¿ÚǧÕ×Èý²ãÍø¹ÜÐͺÐʽ½ÓÈë²ã»¥»»»ú£¬Ç§Õ×ÉÏÐУ¬RG-S2910-48GT4SFP-L

ÎªÔ°ÇøÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæµÄÀûÓÃ

²úÆ·¸öÐÔ£º

  • 48¸ö10/100/1000Base-TÒÔÌ«Íø¶Ë¿Ú
  • 4¸ö¶ÀÁ¢Ç§Õ×SFP¶Ë¿Ú
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬¼ò»¯ÍøÂçÖÎÀí
  • Ö§³ÖCPP/NFPP/RLDP/DHCP snooping¶à³Á°²È«·À»¤Õ½Êõ
  • ·çÀäÉ¢ÈÈ£¬ÖÇÄܵ÷¿ì£¬µÍÔëÇÒ½ÚÄÜ
µ±¼´Õ÷ѯ

²úÆ·¸ÅÊö

RG-S2910-LϵÁл¥»»»úÊÇGA»Æ½ð¼×ÍøÂçÃæÏòÖÐÓ×Ô°ÇøÍÆ³öµÄǧÕ×ÒÔÌ«Íø»¥»»»ú¡£¸ÃϵÁвúƷѡȡȫеÄÓ²¼þ¼Ü¹¹Éè¼Æ£¬´îÔØGA»Æ½ð¼×ÍøÂçRGOS11.XÄ £¿é»¯²Ù×÷ϵͳ£¬¿ÉÌṩ¸ü´óµÄ×ÊÔ´±íÏî¡¢¸ü¿ìµÄÓ²¼þ´¦ÖûúÄÜ¡¢¸ü¸ßµÄ²Ù×÷ʹÓÃÂÄÀú¡£

RG-S2910-LϵÁл¥»»»úÎªÔ°ÇøÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæÀûÓã¬Í¬Ê±Ìṩ´óÈÝÁ¿µÄǧÕ׺ÍÍòÕ×ÉÏÐдø¿í£¬Âú×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔö³¤µÄ±ØÒª¡£

²úÆ·¸öÐÔ

ÃÀÂúµÄ°²È«·À»¤Õ½Êõ

×Ô¶¯·ÀÓùÍøÂçÖеĸ÷ÀàDDoS¹¥»÷£¬ÍøÂçÓÉÓÚÆäÊ¢¿ªÐÔ£¬Ê±Ê±ÓÉÓÚÍÆËã»úϰȾ²¡¶¾£¬»òÊǽÓÈëÍøÂçµÄÈËÔ±³öÓÚ¸÷ÀàÖ÷ÕŶÔÍøÂçÉ豸¡¢ÍøÂçÖеķþÎñÆ÷½øÐй¥»÷£¬µ¼ÖÂÍøÂçÎÞ·¨Õý³£Ê¹Ó᣽ϳ£¼ûµÄÈçARP·ººé¹¥»÷µ¼ÖÂÍø¹ØÎÞ·¨ÏìÓ¦ÒªÇó¡¢ICMP·ººé¹¥»÷µ¼ÖÂÍøÂçÉ豸CPU¸ºÔعý¸ßÎÞ·¨Õý³£¹¤×÷£¬DHCPÒªÇ󷺺鹥»÷£¬µ¼ÖÂDHCP·þÎñÆ÷µØÖ·¿Ý½ß£¬Óû§ÎÞ·¨Õý³£»ñÈ¡IPµØÖ·½Ó¼ûÍøÂç¡£

RG-S2910-LϵÁÐÌṩÏȽøµÄÓ²¼þCPU±£»¤»úÔì£ºÌØÓеÄCPU±£»¤Õ½Êõ£¨CPP£¬CPU Protect Policy£©£¬¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬½øÐÐÁ÷·Ö±æºÍÓÅÏȼ¶¶ÓÁзּ¶´¦Ö㬲¢Æ¾¾Ý±ØÒªÖ´Ðдø¿íÏ޿죬³ä·Ö±£»¤CPU²»±»·¸·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´¿÷Ë𣬱£ÏÕÁËCPU°²È«£¬³ä·Ö±£»¤ÁË»¥»»»úµÄ°²È«¡£

RG-S2910-LϵÁÐÌṩÏȽøµÄ»ù´¡ÍøÂç±£»¤Õ½Êõ£¨NFPP£¬Network Foundation Protection Policy£©¼¼Êõ£¬¿ÉÄÜÏÞ¶Å×û§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÒªÇó±¨ÎÄ¡¢DHCPÒªÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ£¬¶Ô³¬¹ýÏÞ¿ìãÐÖµµÄ±¨ÎĽøÐÐÅׯú´¦Öã¬ÉõÖÁ¿ÉÄܼø±ð¹¥»÷ÐÐΪ£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀë¡£´Ó¶ø±£»¤»ù´¡ÍøÂçÃâÊÜÍøÂç¹¥»÷ÐÐΪµÄÓ°Ï죬±£ÏÕÍøÂç²»±ä¡£

Ö§³ÖDHCP snooping£¬¿ÉÖ»ÔÊÐíÐÅÀµ¶Ë¿ÚµÄDHCPÏìÓ¦£¬Ô¤·À˽ÉèDHCP ServerµÄºýŪ£»²¢ÔÚDHCP¼àÌýµÄ»ù´¡ÉÏ£¬Í¨¹ý¶¯Ì¬¼à²âARPºÍ²é³­Óû§µÄIP£¬Ö±½ÓÅׯú²»Çкϰ󶨱íÏîµÄ·¸·¨±¨ÎÄ£¬ÓÐЧ·À±¸ARPºýŪºÍÓû§Ô´IPµØÖ·µÄºýŪÎÊÌâ¡£

Ðé¹¹»¥»»µ¥Ôª

RG-S2910-LϵÁвúÆ·Ö§³ÖVSU£¨Virtual Switching Unit£¬Ðé¹¹»¥»»µ¥Ôª£©£¬¿ÉÄܽ«¶ą̀ÎïÀíÉ豸½øÐл¥Áª£¬Ê¹ÆäÐ鹹Ϊһ̨Âß¼­É豸£¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet¹ý³Ì¡¢µ¥Ò»ºÅÁîÐнӿڡ¢×Ô¶¯°æ±¾²é³­¡¢×Ô¶¯ÅäÖõȸöÐÔ½øÐÐÖÎÀí£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚÖÎÀíһ̨É豸£¬µ«ÊÇȴʵÏÖ×Ŷą̀É豸´øÀ´µÄ¹¤×÷ЧÄܺÍʹÓÃÂÄÀú¡£

¼ò»¯ÖÎÀí£ºÖÎÀíÔ±Äܹ»¶Ô¶ą̀»¥»»»úͳһÖÎÀí£¬¶ø²»±ØÒªÏνӵ½Ã¿Ì¨»¥»»»ú±ðÀë½øÐÐÅäÖúÍÖÎÀí¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨»¥»»»ú£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍ±íΧÉ豸ÏνÓ£¬²»´æÔÚ¶þ²ã»·Â·£¬Ã»±ØÒªÅäÖÃMSTPºÍ̸£¬¸÷Àà½ÚÔìºÍ̸ÊÇ×÷Ϊһ̨»¥»»»úÔËÐеÄ¡£

ºÁÃë¼¶¹ÊÕϸ´Ô­£ºVSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓ£¬ÈôÊÇÆäÖÐһ̨É豸»òÕßÒ»Ìõ³ÉÔ±Á´Â·³öÏÖ¹ÊÕÏ£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄ¹¦·òÖ»±ØÒªºÁÃë¼¶¡£

¸ßÀ©´óÐÔ£ºÓû§ÐÂÔöµÄÉ豸²ÎÓë»òÍÑÀëÐé¹¹»¯ÍøÂçʱÄܹ»ÊµÏÖ“ÈȲå°Î”£¬²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐС£

±£»¤Í¶×Ê£ºVSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓ£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬ÓÖÄܹ»ÊµÏÖ¸ºÔØÆ½ºâ£¬³ä·ÖÀûÓÃËùÓÐÍøÂçÉ豸ºÍ´ø¿í×ÊÔ´¡£

¸ß¿¿µÃסÐÔ

¶à¹ý³ÌÄ £¿é»¯²Ù×÷ϵͳRGOS 11.X£¬×é¼þ(¹ý³Ì)Ï໥¶ÀÁ¢£¬Ò»¸ö×é¼þ(¹ý³Ì)±ÀÀ£²»»áÓ°Ïìµ½ÆäËû×é¼þ£¬Ö§³ÖÕë¶Ôµ¥Ò»Ä £¿é´òÈȲ¹¶¡£¬¹ÊÕÏÄ £¿éÉý¼¶Öв»Ó°ÏìÆäËû¹ý³ÌµÄÕý³£ÔËÐкÍÒµÎñת·¢¡£

Ö§³ÖÌìÉúÊ÷ºÍ̸802.1D¡¢802.1w¡¢802.1s£¬±£Õϼ±¾çÊÕÁ²£¬Ìá¸ßÈÝ´íÄÜÁ¦£¬±£ÕÏÍøÂçµÄ²»±äÔËÐкÍÁ´Â·µÄ¸ºÔØÆ½ºâ£¬ºÏÀíʹÓÃÍøÂçͨ·£¬ÌṩÈßÓàÁ´Â·ÀûÓÃÂÊ¡£

Ö§³Ö¼±¾çÁ´Â·¼ì²âºÍ̸£¨RLDP£¬Rapid Link Detection Protocol£©£¬¿É¼±¾ç¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²âÖ°ÄÜ£¬Ô¤·À¶Ë¿ÚÏÂÒò˽½ÓHubµÈÉ豸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵľ°Ïó¡£

Ö§³Ö¹«ÓÐÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©£¬¹ú¼Ê³ß¶ÈΪÖ÷ÌâÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝºÍ̸£¬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·¸´Ô­¶¼¼¯ÖÐÔÚÖ÷¿ØÉ豸ÉϽøÐУ¬·ÇÖ÷¿ØÉ豸ֱ½ÓÏòÖ÷¿ØÉ豸»ã±¨×Ô¼ºµÄÁ´Â·Çé¿ö£¬ÎÞÐè¾­¹ýÆäËû·ÇÖ÷¿ØÉ豸µÄ´¦Öã¬Òò¶ø»·Â·ÖжÏÒÔ¼°¸´Ô­¹¦·ò±ÈSTP¿ì¡£»ùÓÚÒÔÉÏÇø±ð£¬ERPSÔÚÃÎÏë»·¾³ÏµÄÁ´Â·¸´Ô­ÄÜÁ¦¿ÉÄÜ´ïµ½ºÁÃë¼¶¡£

Ö§³Ö¼±¾çÒÔÌ«ÍøÉÏÁ´±£»¤ºÍ̸£¨REUP£¬Rapid Ethernet Uplink Protection£©£¬ÔÚ²»ÆôÓÃSTPµÄÇé¿öÏ£¬Äܹ»Ìṩһ¸ö¼±¾çÉÏÁ´±£»¤Ö°ÄÜ£¬REUPʹµÃÓû§ÔڹعØSTPµÄÇé¿öÏ£¬ÈÔÌṩ¸ù»ùµÄÁ´Â·ÈßÓ࣬ͬʱÌṩ±ÈSTP¸ü¿ìµÄºÁÃë¼¶¹ÊÕϸ´Ô­¡£

ÂÌÉ«½ÚÄÜ

RG-S2910-LϵÁл¥»»»ú³ä·ÖÏàÓ¦¹ú¶ÈÂÌÉ«½ÚÄܵĺÅÕÙ£¬Ñ¡È¡¶àÖÖÂÌÉ«½ÚÄܵÄÉè¼ÆÀíÏ룬Õë¶Ô´«Í³»¥»»»úÔÚÔëÒô¼°Äܺķ½Ãæ´æÔÚµÄÎÊÌâ½øÐÐÉî¿Ì×êÑÐË÷Ç󣬳ä·Ö½â¾öÁË»¥»»»ú²¿ÊðÔڰ칫»·¾³ÔëÉù´ó¡¢ÒÔ¼°½ÓÈëÉ豸´óÅúÁ¿²¿Êðºó´øÀ´µÄÄܺĹý´óµÄÎÊÌâ¡£

RG-S2910-LϵÁл¥»»»úѡȡÁËÐÂÒ»´úµÄÓ²¼þ¼Ü¹¹ÒÔ¼°ÏȽøµÄ½ÚÄܵç·Éè¼ÆºÍÔªÆ÷¼þÑ¡ÐÍ£¬ÎªÓû§½Ú¼óÄܺÄ£¬Í¬Ê±½µµÍÔëÒô´«È¾¡£

RG-S2910-LÖ§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬¶Ë¿ÚÈôÊÇÔÚÂ½ÐøÒ»¶Î¹¦·òÖ®ÄÚ¿ÕÏУ¬ÏµÍ³»á½«¸Ã¶Ë¿ÚÉèÖÃΪ½ÚÄÜģʽ£¬µ±Óб¨ÎÄÊÕ·¢Ê±ÔÙͨ¹ý°´Ê±·¢Ë͵ļàÌýÂëÁ÷»½ÐѶ˿ڸ´Ô­ÒµÎñ£¬´ïµ½½ÚÄܵijÉЧ¡£

RG-S2910-LϵÁвúƷͬʱÂú×ã×ÊÁÏ»·±£Ó밲ȫÐÔµÄÅ·ÃËRoHS³ß¶È¡£

µ¥Ò»ÇáËɵÄÍøÂçÊØ»¤

RG-S2910-LϵÁÐÖ§³ÖÔÆÖÎÀí£¬Äܹ»´ø¸ø¿Í»§¼«¼òµÄÔËάÖÎÀíºÍÓû§ÂÄÀú¡£

Ò××éÍø£ºÖ»±ØÒªÒ»Ì¨ÄÜÉÏÍøµÄPC»òÕßÊÖ»ú£¬¼´¿ÉʵÏÖ²¿Ê𣬼´²å¼´Óá£Ö§³Ö»ùÓÚÍø¹ØµÄÍøÂçÍØÆË×Ô¶¯·¢ÏÖ£¬²¢ÒÔͼÐλ¯´ó¾Ö³öÏÖ

Ò×ÔËά£ºÔËάµ¥Ò»£¬ÍøÂçËæÊ±¿É¹Ü£¬ÈËÔÚÄÄÀïÍøÂç¾ÍÔÚÄÄÀÓÐÏßÎÞÏßÍø¹Ø¾¡ÔÚ°ÑÎÕÖС£Ö§³ÖÅäÖÃÏ·¢¡¢ÅäÖñ¸·Ý¡¢ÅäÖø´Ô­¡¢ºÅÁîµ÷ÊÔ¡¢½Ó¼ûeWeb¡¢½Ó¼ûTelnet¡¢½Ó¼ûSSH¡¢³ÁÆô¡¢É豸Éý¼¶

Ò×¼à¿Ø£º¿ÉËæÊ±²é¿´ÍøÂ罡ȫ¶È£¬É豸ÏêÇé(ϵͳ״̬¡¢Á÷Á¿×ßÊÆ¡¢Á¬Í¨ÐÔ¡¢¹©µç״̬µÈ)£¬¹ÊÕÏ¿ÉÊÓ£¬Óû§ÍøÂçÂÄÀú¿ÉÊÓ£¬ÓÐ¸æ¾¯ÊµÊ±ÍÆËÍ£¬ÓÐÈÕÖ¾ÊÂÎñ¹©»ØËÝ¡£Ö§³Ö¸æ¾¯¿Éͨ¹ý΢ÐŹ«¼ÒºÅ¡¢Óʼþ¡¢Î¢ÐÅ¡¢ÆóÒµ¶¤¶¤·¢ËÍÌáÐÑ

Ò×ÈÏÖ¤£ºÒÀ¸½ÔƶË£¬ÕûÍø±ãÄÜÌṩÉÏÍøÊµÃûÈÏÖ¤£¬²»ÓÃÈκεĸ½¼ÓÈí¼þºÍ·þÎñÆ÷¡£

RG-S2910-LϵÁÐÖ§³ÖSNMP¡¢RMON¡¢SyslogµÈ¸öÐÔÀ´½øÐÐÍøÂçµÄÈÕ³£Õï¶Ï¼°ÊØ»¤£¬Í¬Ê±ÖÎÀíÔ±¿ÉѡȡCLI(ºÅÁîÐнӿÚ)¡¢WebÍø¹Ü¡¢TelnetµÈ¶àÑù»¯µÄÖÎÀíºÍÊØ»¤·½Ê½¸ü·½±ãÉ豸µÄÖÎÀí¡£ 

PoEʹÓÃ״̬ÁËÈçÖ¸ÕÆ£ºÃæ°å×Ô´øÒ»¼ü²é¿´PoE¹©µç״ְ̬ÄܵÄPoE°´Å¥£¬Çá°´¼´¿É²é¿´É豸µ±Ç°µÄͨѶ״̬ºÍ¹©µç״̬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

³ß´çÓë³ÁÁ¿

³ß´çÓë³ÁÁ¿ RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4XS-P-L RG-S2910-24GT4SFP-P-L
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 443.0 mm x 268.0 x 44.5 mm (V1.XX/V2.XX)
440 mm x 220 mm x 44 mm (V3.XX¼°ÒÔÉϰ汾)

443.0 mm x 268.0 mm x 44.5 mm (V1.XX)

440mm x 220mm x 44mm (V2.XX¼°ÒÔÉϰ汾)

440 mm × 260 mm × 44 mm

²úÆ·³ÁÁ¿ 3.5 kg (V1.XX/V2.XX)
2.4 kg (V3.XX¼°ÒÔÉϰ汾)
4.00 kg (V1.XX/V2.XX)
2.83 kg (V3.XX¼°ÒÔÉϰ汾)
3.50 kg (V1.XX/V2.XX)
2.45 kg (V3.XX¼°ÒÔÉϰ汾)
4.00 kg (V1.XX)
2.83 kg (V2.XX¼°ÒÔÉϰ汾)
5.5 kg 5.5kg
»ú¼Ü³ß´ç 1 RU
×°Ö÷½Ê½ ×ÀÃæ/±Ú¹Ò/»ú¼Ü/»ú¹ñ

½Ó¿Ú¹æ¸ñ

½Ó¿ÚÓëÄ £¿é RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE SFP½Ó¿Ú
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE SFP½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/10GE SFP+½Ó¿Ú
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/10GE SFP+½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE SFP½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/10GE SFP+½Ó¿Ú
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öRJ45 Console½Ó¿Ú

µçÔ´Ó빦ºÄ

½Ó¿ÚÓëÄ £¿é RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
µçÔ´ 1¸ö¹Ì»¯µçÔ´
Õû»ú×î´ó¹¦ºÄ 24W 40W 24W 50W 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£©
¶î¶¨ÊäÈëµçѹ 100V AC~240V AC£¬50/60Hz
192V DC~290V DC
×î´óÊäÈëµçѹ 90V AC~264V AC£¬50/60Hz
¶î¶¨ÊäÈëµçÁ÷ 0.6A 1.5A 1.5A 1.5A 6.8A 6.8A
PoE½Ó¿Ú ²»Ö§³Ö ²»Ö§³Ö ²»Ö§³Ö ²»Ö§³Ö ½Ó¿Ú1~24Ö§³ÖPoE/PoE+ (IEEE802.3af/at)¹©µç
PoE¹©µçÏß¶Ô ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° Mode A£¨1-2,3-6Ïß¶Ô£©
PoEÊä³ö¹¦ÂÊ ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° ÿ½Ó¿Ú×î´ó¹©µç30W
Õû»ú×î´ó¹©µç370W
×¢Ã÷£ºÏÖʵµÄPoE´øÔØÊýÁ¿£¬ÇëÆ¾¾ÝPoEÊä³ö¹¦Âʼ°PoEÉ豸ÏÖʵ¹¦ÂÊÍÆËã¡£

»·¾³Óë¿¿µÃסÐÔ

»·¾³Óë¿¿µÃסÐÔ RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
ÏßÀÂÈȲå°Î Console¿Ú¡¢ÒµÎñ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ¹¤×÷ζȣº0°C~50°C
´æ´¢Î¶ȣº-40°C~70°C
×¢Ã÷£ºÔÚº£°Î3000Ã×~5000Ã×ÁìÓòÄÚ£¬º£°ÎÿÉý¸ß220Ã×£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£
ʪ¶È ¹¤×÷ʪ¶È£º10%RH~90%RH
´æ´¢Êª¶È£º5%RH~95%RH
µçÉÈ ÎÞµçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ
É¢ÈÈ ÌìȻɢÈÈ ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬²à½øºó³ö ·çÀäÉ¢ÈÈ£¬²à½øºó³ö
ÔëÉù 0dBA £¼47dBA £¼45dBA £¼45dBA £¼78dBA £¼78dBA
µçÔ´¼à¿Ø ²»Ö§³Ö Ö§³Ö¹ÊÕϸ澯
²»Ö§³ÖÄ £¿é¼à¿Ø£¬ÖÇÄÜÉϵç
µçÉÈ¼à¿Ø ²»Éæ¼° Ö§³Ö¹ÊÕϸ澯£¬ÖÇÄܵ÷¿ì£¨²»Ö§³ÖÊÖ¶¯µ÷¿ì£©
Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ
ÎÂ¶È¼à¿Ø Ö§³ÖÎÂ¶È¼à¿Ø£¬Î¶ȸ澯£¬¹ýα£»¤
·ÀÀ× 10kV

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
»¥»»ÈÝÁ¿ 598Gbps/5.98Tbps 598Gbps/5.98Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 598Gbps/5.98Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps 166Mpps 126Mpps 166Mpps 126Mpps 126Mpps

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S2910-24GT4SFP-L
RG-S2910-48GT4SFP-L
RG-S2910-24GT4XS-L
RG-S2910-48GT4XS-L
RG-S2910-24GT4SFP-P-L
RG-S2910-24GT4XS-P-L
PoE ²»Ö§³Ö ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷdz߶ÈPDÉ豸
Ö§³Ö¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
¶þ²ã»·Íø¼¼Êõ Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS£¬Çл»¹¦·ò≤50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·ÃÀÂú¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½Ê½ /×î´ó¿É¾ÛºÏ¿ÚÊýÁ¿ÅäÖÃ
Ö§³Ö¿çVSU AP
Mirror Ö§³Öͨ³£ÒµÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ö÷ÕŶ˿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢RSPAN
Ö§³Ö¿çÉ豸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
VSU¸öÐÔ Ö§³ÖVSUÐé¹¹»¯¼¼Êõ
Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Öͨ¹ý³ß¶ÈÒµÎñ»°±úÏÖÐé¹¹»¯
IP·ÓÉ IPv4/IPv6¾²Ì¬Â·ÓÉ¡¢¿ÉÀ©´óÖ§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ºÍ̸
ACL Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³ÖACL80
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACL³Á¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È
°²È«¸öÐÔ ¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
EEE Ö§³ÖIEEE 802.3az³ß¶ÈµÄEEE£¨Energy Efficient Ethernet£¬½ÚÄÜÒÔÌ«Íø£©¼¼Êõ
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢WIS¹«ÓÐÔÆÆ½Ì¨ÖÎÀí
·¢Õ¹¾ßÌå²ÎÊý

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÀûÓð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
PoE¹©µç(1)
É¢ÈÈ(1)
½ÚÄÜ(1)
»·Íø±£»¤(1)
IPv6ºÍ̸(1)
Èý²ã»¥»»»ú(2)
¶Ë¿Ú¾ÛºÏ(1)
»·Â·¼ì²â(1)
aaaºÍ̸(1)
SNMP°æ±¾(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
ÎÒÃÇ»ú·¿×ó½üÓлáÒéÊÒ£¬±ÈÁ¦²»°²»¥»»»úÔëÒôÎÊÌ⣬ÇëÎÊRG-S2910-24GT4SFP-LÕâ¿î»¥»»»úÊÇ·ñÊʺÏʹÓÃÄØ £¿
ÓÐЧ 58 ÎÞÓà 16

Äܹ»µÄ£¬RG-S2910-24GT4SFP-LÕâ¿î»¥»»»úѡȡÎÞµçÉÈÉè¼Æ£¬ÌìȻɢÈÈ£¬ÎÞÔëÒô£¬¼´±ãÀë°ì¹«ÊҺܽüÒ²²»Óò»°²ÔëÒôÎÊÌ⣻ͬʱËü»¹Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬¶Ë¿Ú×Ô¶¯ÐÝÃߣ¬½Ú¼óÉ豸ÄܺÄ¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S2910-24GT4SFP-LÖ§³Ö»ùÓÚIPv6 ºÍ̸µÄÖÎÀí·½Ê½£¬Ô̺¬ Telnet¡¢ SSH-2 ·½Ê½Â𠣿֧³ÖÒÔÌ«Íø»·Íø±£»¤Ö°ÄÜÂ𠣿
ÓÐЧ 60 ÎÞÓà 15

ÕâЩ¶¼ÊÇÖ§³ÖµÄ£¬¾ßÌåÄÚÈÝÒ²Äܹ»²é¿´Ö§³ÖµÄÈí¼þºÍ̸°å¿éºÍ²úÆ·²ÊÒ³¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ £¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖà £¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ £¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Òé £¿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿