GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
RG-S2910-24GT4XS-P-L
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

RG-S2910-P-LϵÁÐ24¿ÚǧÕ×Èý²ãÍø¹ÜÐͺÐʽ½ÓÈë²ãPoE»¥»»»ú£¬ÍòÕ×ÉÏÐУ¬RG-S2910-24GT4XS-P-L

ÎªÔ°ÇøÍøÂç½ÓÈëÉ豸ÌṩǧÕ×µ½×ÀÃæµÄÀûÓã¬Í¬Ê±Âú×ã°²·À¼à¿Ø¡¢µç»°»áÒéϵͳ¡¢ÎÞÏ߸²¸ÇµÈ³£¼ûPoE¹©µçµÄÐèÒª¡£

²úÆ·¸öÐÔ£º

  • 24¸ö10/100/1000Base-TÒÔÌ«Íø¿Ú£¬Ö§³ÖPoE¹©µç£¬µ¥¶Ë¿Ú×î´ó¹¦ÂÊ´ï30W
  • 4¸ö¶ÀÁ¢ÍòÕ×SFP+¹â¿Ú
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬¼ò»¯ÍøÂçÖÎÀí
  • Ö§³ÖCPP/NFPP/RLDP/DHCP snooping¶à³Á°²È«·À»¤Õ½Êõ
  • ·çÀäÉ¢ÈÈ£¬ÖÇÄܵ÷¿ì£¬µÍÔëÇÒ½ÚÄÜ
µ±¼´Õ÷ѯ

Èí¼þºÍ̸

gaokekao
¸ß¿¿µÃסÐÔ
VSU
STP/RSTP/MSTP
DLDP
RLDP/LLDP
yinyongxieyi
ÀûÓúÍ̸
DNS
DHCP Relay
DHCP Server
DHCP Client
Telnet
FTP¡¢TFTP
NTP¡¢SNTP
Mirror
VLAN
¸ù»ùQinQ/½Ã½ÝQinQ
guanlitexing
ÖÎÀí¸öÐÔ
SNMP
RMON
Syslog/Debug
NTP/SNTP
WebÖÎÀí¡¢CLI(Telnet/Console)¡¢SSH
anquantexing
°²È«¸öÐÔ
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
RADIUS
TACACS+
BPDU Guard
CPP¡¢NFPP
¶Ë¿Ú±£»¤
802.1X
·ÀÍø¹ØARPºýŪ
ACL/QoS
DHCP snooping/IGMP SNOOPING

24¿ÚǧÕ×Èý²ãÍø¹ÜÐÍPoE»¥»»»ú
RG-S2910-24GT4XS-P-L

×ñÑ­IEEE 802.3afºÍIEEE 802.3at³ß¶È£¬Ö§³ÖPoE+¹©µç£¬Âú×ã°²·À¼à¿Ø¡¢µç»°»áÒéϵ
ͳ¡¢ÎÞÏ߸²¸ÇµÈ³£¼ûPoE¹©µçµÄÐèÒª
¿´¶Ë¿Ú
¿´ÀûÓÃ
page1-img
page1-img-2
Union

IEEE 802.3af/at³ß¶È

Group1460

¹©µç¶Ë¿ÚÓÅÏȼ¶ÉèÖÃ

Group1461

×Ô½ç˵¹©µç¹¦·ò¶ÎÉèÖÃ

¶à³Á°²È«·À»¤Õ½Êõ£¬Ô¤·ÀÍøÂç¹¥»÷£¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ

°²È«¿¿µÃס
²»±äÔËÐÐ
Ö§³ÖMACµØÖ·¡¢802.1X¡¢RadiusµÈ¶àÖÖÈÏÖ¤·½Ê½£¬ÓÐЧ½ÚÔìÓû§½Ó¼ûȨÏÞ
Ö§³ÖÃÀÂúµÄDoSÀà·À¹¥»÷£¬Ö§³ÖDHCP snooping£¬·À±¸ºÚ¿Í¡¢²¡¶¾¶ñÒâ¹¥»÷£¬±£ÕÏÍøÂç²»±äÔËÐÐ
ÌṩCPU±£»¤Õ½Êõ£¬½ÚÔì·¢ÍùCPUµÄ±¨ÎÄÀàÐͺÍÁ÷Á¿´óÓ×£¬±£»¤CPUÀûÓÃÂÊ
Ìṩ»ù´¡ÍøÂç±£»¤Õ½Êõ£¨NFPP£©£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀ룬±£ÕÏÍøÂ簲ȫ²»±ä
page2-img-tab1_750
page2-img-tab2_750

Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬Ê¹ÍøÂç¸ßЧÔËÐв»¼ä¶Ï

¼ò»¯ÍøÂçÖÎÀí
ºÁÃë¼¶¹ÊÕϸ´Ô­
¸ßÀ©´óÐÔ
Ö§³ÖVSUÐé¹¹»¯¼¼Êõ£¬¿É½«¶ą̀ÎïÀíÉ豸Ð鹹Ϊһ̨Âß¼­É豸
¶Ô¶ą̀»¥»»»úͳһÖÎÀí£¬ÎÞÐè±ðÀëÅäÖúÍÖÎÀí
VSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓ
ÈçÓö¹ÊÕÏ£¬¿ÉºÁÃë¼¶Çл»Á´Â·£¬±£ÕÏÍøÂç²»¼ä¶Ï
ÐÂÔöµÄÉ豸²ÎÓë»òÍÑÀëÐé¹¹»¯ÍøÂçʱÄܹ»ÊµÏÖ“ÈȲå°Î”
²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐÐ
page3-img
page3-img-2_750
page3-img-3_750

·çÀäÉ¢ÈÈ£¬ÖÇÄܵ÷¿ì£¬½µÔëÇÒ½ÚÄÜ

ÄÚÖÃ1¸ö¹Ì»¯µçÉÈ£¬·çÀäÉ¢ÈÈ£¬ÖÇÄܵ÷¿ì£¬µ±¶Ë¿ÚÁ÷Á¿½ÏÓ×»òÎÞÁ÷Á¿Ê±£¬ÖÇÄܽµµÍ¶Ë¿Ú¹¦ÂÊ
»òÐÝÃßÎÞÁ÷Á¿¶Ë¿Ú£¬½µµÍÔëÒô½Ú¼ó¹¦ºÄ£¬µ¢¸éÉ豸ʹÓÃÊÙÃü¡£
page4-bg_750
page4-icon1

¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©

page4-icon2

Å·ÃËRoHS³ß¶È

page4-icon3

¶Ë¿Ú×Ô¶¯ÐÝÃß

Ö§³Ö¶àÖÖÖÎÀí·½Ê½£¬Ìá¸ßÍøÂç¿É½ÚÔìÐԺͰ²È«ÐÔ

µ¥É豸ÖÎÀí
¶àÉ豸ÖÎÀí
¿ÉѡȡWebÖÎÀí¡¢CLI(ºÅÁîÐнӿÚ)µÈ¶àÑù»¯µÄ±¾µØ»¯ÖÎÀíºÍÊØ»¤·½Ê½£¬É豸ÖÎÀí·½±ã¼°°²È«
Ö§³ÖSNMPºÍ̸£¬¿É¶Ô½ÓµÚÈý·½ÍøÂçÖÎÀíÆ½Ì¨£¬ÊµÏÖ¶Ô·ÖÆçÆ·ÅÆÉ豸µÄͳһÖÎÀí£¬ÍøÂçÔËάºÍÖÎÀí¸ü¸ßЧ
web
disanfan

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

³ß´çÓë³ÁÁ¿

³ß´çÓë³ÁÁ¿ RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4XS-P-L RG-S2910-24GT4SFP-P-L
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 443.0 mm x 268.0 x 44.5 mm (V1.XX/V2.XX)
440 mm x 220 mm x 44 mm (V3.XX¼°ÒÔÉϰ汾)

443.0 mm x 268.0 mm x 44.5 mm (V1.XX)

440mm x 220mm x 44mm (V2.XX¼°ÒÔÉϰ汾)

440 mm × 260 mm × 44 mm

²úÆ·³ÁÁ¿ 3.5 kg (V1.XX/V2.XX)
2.4 kg (V3.XX¼°ÒÔÉϰ汾)
4.00 kg (V1.XX/V2.XX)
2.83 kg (V3.XX¼°ÒÔÉϰ汾)
3.50 kg (V1.XX/V2.XX)
2.45 kg (V3.XX¼°ÒÔÉϰ汾)
4.00 kg (V1.XX)
2.83 kg (V2.XX¼°ÒÔÉϰ汾)
5.5 kg 5.5kg
»ú¼Ü³ß´ç 1 RU
×°Ö÷½Ê½ ×ÀÃæ/±Ú¹Ò/»ú¼Ü/»ú¹ñ

½Ó¿Ú¹æ¸ñ

½Ó¿ÚÓëÄ£¿é RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE SFP½Ó¿Ú
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE SFP½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/10GE SFP+½Ó¿Ú
48¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/10GE SFP+½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE SFP½Ó¿Ú
24¸ö10/100/1000Base-T×ÔÊÊÓ¦ÒÔÌ«Íø½Ó¿Ú
4¸ö1GE/10GE SFP+½Ó¿Ú
¹Ì»¯ÖÎÀí½Ó¿Ú 1¸öRJ45 Console½Ó¿Ú

µçÔ´Ó빦ºÄ

½Ó¿ÚÓëÄ£¿é RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
µçÔ´ 1¸ö¹Ì»¯µçÔ´
Õû»ú×î´ó¹¦ºÄ 24W 40W 24W 50W 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£©
¶î¶¨ÊäÈëµçѹ 100V AC~240V AC£¬50/60Hz
192V DC~290V DC
×î´óÊäÈëµçѹ 90V AC~264V AC£¬50/60Hz
¶î¶¨ÊäÈëµçÁ÷ 0.6A 1.5A 1.5A 1.5A 6.8A 6.8A
PoE½Ó¿Ú ²»Ö§³Ö ²»Ö§³Ö ²»Ö§³Ö ²»Ö§³Ö ½Ó¿Ú1~24Ö§³ÖPoE/PoE+ (IEEE802.3af/at)¹©µç
PoE¹©µçÏß¶Ô ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° Mode A£¨1-2,3-6Ïß¶Ô£©
PoEÊä³ö¹¦ÂÊ ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° ²»Éæ¼° ÿ½Ó¿Ú×î´ó¹©µç30W
Õû»ú×î´ó¹©µç370W
×¢Ã÷£ºÏÖʵµÄPoE´øÔØÊýÁ¿£¬ÇëÆ¾¾ÝPoEÊä³ö¹¦Âʼ°PoEÉ豸ÏÖʵ¹¦ÂÊÍÆËã¡£

»·¾³Óë¿¿µÃסÐÔ

»·¾³Óë¿¿µÃסÐÔ RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
ÏßÀÂÈȲå°Î Console¿Ú¡¢ÒµÎñ½Ó¿ÚÓëµçÔ´½Ó¿ÚÖ§³Ö
ÎÂ¶È ¹¤×÷ζȣº0°C~50°C
´æ´¢Î¶ȣº-40°C~70°C
×¢Ã÷£ºÔÚº£°Î3000Ã×~5000Ã×ÁìÓòÄÚ£¬º£°ÎÿÉý¸ß220Ã×£¬×î¸ßζȹæ¸ñ½µµÍ1¡æ¡£
ʪ¶È ¹¤×÷ʪ¶È£º10%RH~90%RH
´æ´¢Êª¶È£º5%RH~95%RH
µçÉÈ ÎÞµçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ 1¸ö¹Ì»¯µçÉÈ
É¢ÈÈ ÌìȻɢÈÈ ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬ÓÒ½ø×ó³ö ·çÀäÉ¢ÈÈ£¬²à½øºó³ö ·çÀäÉ¢ÈÈ£¬²à½øºó³ö
ÔëÉù 0dBA £¼47dBA £¼45dBA £¼45dBA £¼78dBA £¼78dBA
µçÔ´¼à¿Ø ²»Ö§³Ö Ö§³Ö¹ÊÕϸ澯
²»Ö§³ÖÄ£¿é¼à¿Ø£¬ÖÇÄÜÉϵç
µçÉÈ¼à¿Ø ²»Éæ¼° Ö§³Ö¹ÊÕϸ澯£¬ÖÇÄܵ÷¿ì£¨²»Ö§³ÖÊÖ¶¯µ÷¿ì£©
Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ
ÎÂ¶È¼à¿Ø Ö§³ÖÎÂ¶È¼à¿Ø£¬Î¶ȸ澯£¬¹ýα£»¤
·ÀÀ× 10kV

ϵͳ¹æ¸ñ

ϵͳ¹æ¸ñ RG-S2910-24GT4SFP-L RG-S2910-48GT4SFP-L RG-S2910-24GT4XS-L RG-S2910-48GT4XS-L RG-S2910-24GT4SFP-P-L RG-S2910-24GT4XS-P-L
»¥»»ÈÝÁ¿ 598Gbps/5.98Tbps 598Gbps/5.98Tbps 672Gbps/6.72Tbps 672Gbps/6.72Tbps 598Gbps/5.98Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps 166Mpps 126Mpps 166Mpps 126Mpps 126Mpps

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S2910-24GT4SFP-L
RG-S2910-48GT4SFP-L
RG-S2910-24GT4XS-L
RG-S2910-48GT4XS-L
RG-S2910-24GT4SFP-P-L
RG-S2910-24GT4XS-P-L
PoE ²»Ö§³Ö ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af£¨15.4W£©¡¢IEEE 802.3at£¨30W£©
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷdz߶ÈPDÉ豸
Ö§³Ö¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç
MACµØÖ·±í Ö§³Ö¾²Ì¬MACµØÖ·
Ö§³ÖMACµØÖ·¹ýÂË
802.1Q VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
¶þ²ã»·Íø¼¼Êõ Ö§³ÖG.8032¹ú¼Ê³ß¶È»·ÍøºÍ̸ERPS£¬Çл»¹¦·ò≤50ms£¬¿ÉÓëÆäËûÖ§³Ö¸ÃºÍ̸µÄ²úÆ·ÃÀÂú¼æÈÝ
¶Ë¿Ú¾ÛºÏ Ö§³ÖÁ÷Á¿Æ½ºâ·½Ê½
Ö§³ÖLACP¶¯Ì¬¾ÛºÏ
Ö§³ÖLACPÓÅÏȼ¶/ЭÉÌ·½Ê½ /×î´ó¿É¾ÛºÏ¿ÚÊýÁ¿ÅäÖÃ
Ö§³Ö¿çVSU AP
Mirror Ö§³Öͨ³£ÒµÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ö÷ÕŶ˿Ú
Ö§³Ö»ùÓÚÁ÷¡¢»ùÓÚVLANµÄ¶Ë¿Ú¾µÏñ
Ö§³ÖÒ»¶ÔÒ»¡¢RSPAN
Ö§³Ö¿çÉ豸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
VSU¸öÐÔ Ö§³ÖVSUÐé¹¹»¯¼¼Êõ
Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Öͨ¹ý³ß¶ÈÒµÎñ»°±úÏÖÐé¹¹»¯
IP·ÓÉ IPv4/IPv6¾²Ì¬Â·ÓÉ¡¢¿ÉÀ©´óÖ§³ÖRIP¡¢RIPng¡¢OSPF¡¢OSPFv3ºÍ̸
ACL Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³ÖACL80
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACL³Á¶¨Ïò
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCP/TOSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢ SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È
°²È«¸öÐÔ ¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤
Ö§³ÖRADIUS ºÍ TACACS+
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú±£»¤
EEE Ö§³ÖIEEE 802.3az³ß¶ÈµÄEEE£¨Energy Efficient Ethernet£¬½ÚÄÜÒÔÌ«Íø£©¼¼Êõ
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢WIS¹«ÓÐÔÆÆ½Ì¨ÖÎÀí
·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÀûÓð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
PoE¹©µç(1)
É¢ÈÈ(1)
½ÚÄÜ(1)
»·Íø±£»¤(1)
IPv6ºÍ̸(1)
Èý²ã»¥»»»ú(2)
¶Ë¿Ú¾ÛºÏ(1)
»·Â·¼ì²â(1)
aaaºÍ̸(1)
SNMP°æ±¾(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
ÎÒÃÇ»ú·¿×ó½üÓлáÒéÊÒ£¬±ÈÁ¦²»°²»¥»»»úÔëÒôÎÊÌ⣬ÇëÎÊRG-S2910-24GT4SFP-LÕâ¿î»¥»»»úÊÇ·ñÊʺÏʹÓÃÄØ£¿
ÓÐЧ 58 ÎÞÓà 16

Äܹ»µÄ£¬RG-S2910-24GT4SFP-LÕâ¿î»¥»»»úѡȡÎÞµçÉÈÉè¼Æ£¬ÌìȻɢÈÈ£¬ÎÞÔëÒô£¬¼´±ãÀë°ì¹«ÊҺܽüÒ²²»Óò»°²ÔëÒôÎÊÌ⣻ͬʱËü»¹Ö§³Ö¸ßЧ½ÚÄÜÒÔÌ«Íø£¨EEE£©£¬¶Ë¿Ú×Ô¶¯ÐÝÃߣ¬½Ú¼óÉ豸ÄܺÄ¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S2910-24GT4SFP-LÖ§³Ö»ùÓÚIPv6 ºÍ̸µÄÖÎÀí·½Ê½£¬Ô̺¬ Telnet¡¢ SSH-2 ·½Ê½Âð£¿Ö§³ÖÒÔÌ«Íø»·Íø±£»¤Ö°ÄÜÂð£¿
ÓÐЧ 60 ÎÞÓà 15

ÕâЩ¶¼ÊÇÖ§³ÖµÄ£¬¾ßÌåÄÚÈÝÒ²Äܹ»²é¿´Ö§³ÖµÄÈí¼þºÍ̸°å¿éºÍ²úÆ·²ÊÒ³¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿