RG-S2910-24GT4SFP-UP-H
RG-S2910-24GT4SFP-UP-H
RG-S2910-24GT4SFP-UP-H
RG-S2910-24GT4SFP-UP-H
RG-S2910-24GT4SFP-UP-H
RG-S2910-24GT4SFP-UP-H
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

24¿ÚǧÕ×µç½ÓÈ뻥»»»ú£¬4¸öǧÕ×ÉÏÐпÚ£¬RG-S2910-24GT4SFP-UP-H

ÖÇÄܹ¹Öþ³¡¾°Öи÷Ààϵͳ´ó¹¦ÂÊÖն˵ÄPoEÔ¶³Ì¹©µç £»¸÷ÀàÊÒ±íÎÞÏß²¿Ê𳡾°£¬Âú×ãÊÒ±í´ó¹¦ÂÊÎÞÏß½ÓÈëµãµÄ¹©µçÐèÒª

²úÆ·¸öÐÔ£º

  • ´ó¹¦ÂÊÔ¶³Ì¹©µç£¬ÈÃÄÜÁ¿´©¹ýÍøÂç
  • ÍøÏßµçÏߺÏÒ»£¬²¿Êðµ¥Ò»
  • ´ÓÉ豸µ½¹©µç¡¢ÔÙµ½ÍøÂ磬ÈýάһÌå±£ÏÕ°²È«²»±ä
  • Ô¶³Ì³ÁÆô£¬ÇáËÉÔËά
µ±¼´Õ÷ѯ

²úÆ·¸ÅÊö

RG-S2910-HϵÁл¥»»»úÊÇGA»Æ½ð¼×ÍøÂçÃæÏò°²È«¡¢¸ßЧºÍ½ÚÄܵÄÉè¼ÆÀíÏëÍÆ³öµÄÐÂÒ»´úǧÕ×ÒÔÌ«Íø»¥»»»ú£¬¿ÉÌṩȫǧÕ×½ÓÈëºÍ½Ã½ÝÀ©´óµÄÍòÕ×ÉÏÐÐÊý¾Ý½»»¥ÄÜÁ¦¡£¸ÃϵÁвúƷѡȡȫеÄÓ²¼þ¼Ü¹¹Éè¼Æ£¬´îÔØGA»Æ½ð¼×ÍøÂç×îеÄRGOS11.XÄ£¿é»¯²Ù×÷ϵͳ£¬¿ÉÌṩ¸ü´óµÄ×ÊÔ´±íÏî¡¢¸ü¿ìµÄÓ²¼þ´¦ÖûúÄÜ¡¢¸ü¸ßµÄ²Ù×÷ʹÓÃÂÄÀú¡£³ä·ÖÂú×ãÓû§¸ßÃܶȽÓÈëµÄÐèÒª£¬·ÖÆçÅäÖõÄPoE»úÐÍ»¹¿ÉÂú×ãÕû»úËùÓÐÏÂÐж˿ÚPoE+¸ºÔصĽÓÈëÐèÒªºÍÍòÕ×ÉÏÁªµÄ¸ß´ø¿íÐèÒª¡£

²úÆ·¸öÐÔ

ÍøÂ簲ȫ

Ö§³¸÷ÖÖÖÀàÐÍACL¡¢¶Ë¿Ú°²È«¡¢IP+MAC+Port°ó¶¨µÈ¼¼Êõ£¬¿ÉÄÜÓÐЧԤ·À¸÷ÀàARPºýŪ£¬²¢ÇҾ߱¸×Ô¶¯·À»¤¸÷ÀàDoS¡¢DDoS¹¥»÷µÄÄÜÁ¦¡£

Ö§³ÖGA»Æ½ð¼×ÍøÂçÌØÓеÄCPU± £»¤Õ½Êõ£¨CPP£¬CPU Protect Policy£©ºÍ»ù´¡ÍøÂç± £»¤Õ½Êõ£¨NFPP£¬Network Foundation Protection Policy£©£¬¿É¶Ô·¢ÍùCPUµÄÊý¾ÝÁ÷£¬½øÐÐÁ÷·Ö±æºÍÓÅÏȼ¶¶ÓÁзּ¶´¦Ö㬲¢Æ¾¾Ý±ØÒªÊµÊ±´ø¿íÏ޿죬³ä·Ö± £»¤CPU²»±»·¸·¨Á÷Á¿Õ¼ÓᢶñÒâ¹¥»÷ºÍ×ÊÔ´¿÷Ë𣬱£ÏÕÁËCPU²»±äÔËÐС£Í¬Ê±£¬¿ÉÄÜÏÞ¶Å×û§ÏòÍøÂçÖз¢ËÍARP±¨ÎÄ¡¢ICMPÒªÇó±¨ÎÄ¡¢DHCPÒªÇó±¨ÎĵÈÊý¾Ý°üµÄÊýÂÊ£¬¶Ô³¬¹ýÏÞ¿ìãÐÖµµÄ±¨ÎĽøÐÐÅׯú´¦Öã¬ÉõÖÁ¿ÉÄܼø±ð¹¥»÷ÐÐΪ£¬¶ÔÓй¥»÷ÐÐΪµÄÓû§½øÐиôÀ룬±£ÕÏÉ豸ºÍÕûÍøµÄ°²È«²»±äÔËÐС£

Ö§³Ö¼±¾çÁ´Â·¼ì²âºÍ̸£¨RLDP£¬Rapid Link Detection Protocol£©£¬¿É¼±¾ç¼ì²âÁ´Â·µÄͨ¶ÏºÍ¹âÏËÁ´Â·µÄµ¥ÏòÐÔ£¬²¢Ö§³Ö¶Ë¿ÚÏµĻ·Â·¼ì²âÖ°ÄÜ£¬Ô¤·À¶Ë¿ÚÏÂÒò˽½ÓHubµÈÉ豸ÐγɵĻ·Â·¶øµ¼ÖÂÍøÂç¹ÊÕϵľ°Ïó

Ðé¹¹»¥»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©

RG-S2910-HϵÁвúÆ·Ö§³ÖÐé¹¹»¥»»µ¥Ôª£¨VSU£¬Virtual Switching Unit£©¡£¿ÉÄܽ«¶ą̀ÎïÀíÉ豸½øÐл¥Áª£¬Ê¹ÆäÐ鹹Ϊһ̨Âß¼­É豸£¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet¹ý³Ì¡¢µ¥Ò»ºÅÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾²é³­¡¢×Ô¶¯ÅäÖõȸöÐÔ½øÐÐÖÎÀí£¬¶ÔÓû§À´Ëµ½ö½öÊÇÔÚÖÎÀíһ̨É豸£¬µ«ÊÇȴʵÏÖ×Ŷą̀É豸´øÀ´µÄ¹¤×÷ЧÄܺÍʹÓÃÂÄÀú¡£

¼ò»¯ÖÎÀí£ºÖÎÀíÔ±Äܹ»¶Ô¶ą̀»¥»»»úͳһÖÎÀí£¬¶ø²»±ØÒªÏνӵ½Ã¿Ì¨»¥»»»ú±ðÀë½øÐÐÅäÖúÍÖÎÀí¡£

¼ò»¯ÍøÂçÍØÆË£ºVSUÔÚÍøÂçÖÐÏ൱ÓÚһ̨»¥»»»ú£¬Í¨¹ý¾ÛºÏÁ´Â·ºÍ±íΧÉ豸ÏνÓ£¬²»´æÔÚ¶þ²ã»·Â·£¬Ã»±ØÒªÅäÖÃMSTPºÍ̸£¬¸÷Àà½ÚÔìºÍ̸ÊÇ×÷Ϊһ̨»¥»»»úÔËÐеÄ¡£

ºÁÃë¼¶¹ÊÕϸ´Ô­£ºVSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓ£¬ÈôÊÇÆäÖÐһ̨É豸»òÕßÒ»Ìõ³ÉÔ±Á´Â·³öÏÖ¹ÊÕÏ£¬Çл»µ½ÁíÒ»Ìõ³ÉÔ±Á´Â·µÄ¹¦·òÖ»±ØÒª50µ½200ºÁÃë¡£

¸ßÀ©´óÐÔ£ºÓû§ÐÂÔöµÄÉ豸²ÎÓë»òÍÑÀëÐé¹¹»¯ÍøÂçʱÄܹ»ÊµÏÖ¡°ÈȲå°Î¡±£¬²»Ó°ÏìÆäËûÉ豸µÄÕý³£ÔËÐС£

± £»¤Í¶×Ê£ºVSUºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓ£¬¼ÈÌṩÁËÈßÓàÁ´Â·£¬ÓÖÄܹ»ÊµÏÖ¸ºÔØÆ½ºâ£¬³ä·ÖÀûÓÃËùÓÐÍøÂçÉ豸ºÍ´ø¿í×ÊÔ´¡£Í¬Ê±¿ÉÓÃËÁÒâ״̬µÄÍòÕ×¶Ë¿Úͨ¹ýËÁÒâµÄÊý¾Ý´«ÊäÏßÀÂ×é³ÉVSUÐé¹¹ÍøÂçϵͳ£¬²»±ØÒª¶î±íÅäÖÃÏßÀ¡¢À©´ó¿¨£¬²¢ÇÒûÓж˿ںÍÏßÀÂÖÖÀàµÄÏÞ¶È£¬×î´óÏ޶ȱ £»¤Óû§µÄͶ×Ê¡£

³ß¶ÈºÍ̸£¬É豸¶Ô½Ó¸üÈÝÒ×

Ö§¹«ÓÐÒÔÌ«Íø¶à»·± £»¤¼¼Êõ£¨ERPS£©£¬¹ú¼Ê³ß¶ÈΪÖ÷ÌâÒÔÌ«ÍøÉè¼ÆµÄ¶þ²ãÁ´Â·ÈßÓ౸·ÝºÍ̸£¬Æä»·Â·×è¶ÏÒÔ¼°Á´Â·¸´Ô­¶¼¼¯ÖÐÔÚÖ÷¿ØÉ豸ÉϽøÐУ¬·ÇÖ÷¿ØÉ豸ֱ½ÓÏòÖ÷¿ØÉ豸»ã±¨×Ô¼ºµÄÁ´Â·Çé¿ö£¬ÎÞÐè¾­¹ýÆäËû·ÇÖ÷¿ØÉ豸µÄ´¦Öã¬Òò¶ø»·Â·ÖжÏÒÔ¼°¸´Ô­¹¦·ò±ÈSTP¿ì¡ £»ùÓÚÒÔÉÏÇø±ð£¬ERPSÔÚÃÎÏë»·¾³ÏµÄÁ´Â·¸´Ô­ÄÜÁ¦¿ÉÄÜ´ïµ½ºÁÃë¼¶¡£

µ¥Ò»ÇáËɵÄÍøÂçÊØ»¤

Ö§³ÖSNMP¡¢RMON¡¢Syslog¡¢sFLOWµÈ¸öÐÔÀ´½øÐÐÍøÂçµÄÈÕ³£Õï¶Ï¼°ÊØ»¤£¬Í¬Ê±ÖÎÀíÔ±¿ÉѡȡCLI¡¢WebÍø¹Ü¡¢Telnet¡¢CWMP(TR069)ÁãÅäÖõȶàÑù»¯µÄÖÎÀíºÍÊØ»¤·½Ê½¸ü·½±ãÉ豸µÄÖÎÀí¡£

PoEʹÓÃ״̬ÁËÈçÖ¸ÕÆ£ºÃæ°å×Ô´øÒ»¼ü²é¿´PoE¹©µç״ְ̬ÄܵÄPoE°´Å¥£¬Çá°´¼´¿É²é¿´É豸µ±Ç°µÄͨѶ״̬ºÍ¹©µç״̬£¬ÈÃÄú¶ÔËùÓж˿ÚPoE¹©µçµÄ״̬ÁËÈ»ÓÚÐÄ¡£

Ö§³Ö»ùÓÚSNMP¡¢ERSPAN¡¢NetconfµÈ¼¼ÊõµÄTelemetry£¬ÊµÏÖ¶Ô»¥»»»úÔËÐÐ״̬ÐÅÏ¢µÄ²É¼¯¡£

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

Ó²¼þ¹æ¸ñ RG-S2910-24GT4SFP-UP-H RG-S2910-24GT4XS-UP-H
½Ó¿Ú¹æ¸ñ
¹Ì»¯ÒµÎñ½Ó¿Ú 24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸öǧÕ×SFP¹â¿Ú 24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú£¬4¸ö1G/10G SFP+¹â¿Ú
ϵͳ¹æ¸ñ
»¥»»ÈÝÁ¿ 672Gbps/6.72Tbps 672Gbps/6.72Tbps
°üת·¢ÂÊ 126Mpps 171Mpps
³ß´çÓë³ÁÁ¿
²úÆ·³ß´ç£¨¿í¡ÁÉî¡Á¸ß£© V6.XX¼°ÒÔϰ汾£º440mm x 260mm x 44mm
V7.XX°æ±¾£º440mm x 220mm x 43.6mm
V4.XX¼°ÒÔϰ汾£º440mm x 260mm x 44mm
V5.XX°æ±¾£º440mm x 220mm x 43.6mm
²úÆ·³ÁÁ¿ V6.XX¼°ÒÔϰ汾£º5.5 kg£¨º¬°ü×°£©
V7.XX°æ±¾£º2.85 kg
V4.XX¼°ÒÔϰ汾£º5.5 kg£¨º¬°ü×°£©
V5.XX°æ±¾£º2.85 kg
µçÔ´Ó빦ºÄ
µçÔ´ÊäÈë
  • V6.XX¼°ÒÔϰ汾

»¥»»£¨AC£©ÊäÈ룺
¶î¶¨µçѹÁìÓò100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹÁìÓò90V~264V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹÁìÓò192V~290V
  • V7.XX°æ±¾

»¥»»£¨AC£©ÊäÈ룺
¶î¶¨µçѹÁìÓò100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹÁìÓò90V~290V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹÁìÓò190V~290V
  • V4.XX¼°ÒÔϰ汾

»¥»»£¨AC£©ÊäÈ룺
¶î¶¨µçѹÁìÓò100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹÁìÓò90V~264V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹÁìÓò192V~290V
  • V5.XX°æ±¾

»¥»»£¨AC£©ÊäÈ룺
¶î¶¨µçѹÁìÓò100V~240V£¬ÆµÂÊ50/60Hz
×î´óµçѹÁìÓò90V~290V£¬ÆµÂÊ50/60Hz
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺
ÊäÈëµçѹÁìÓò190V~290V
PoE¹©µç³ß¶È 24¸öµç¿ÚÖ§³ÖPoEºÍPoE+ 24¸öµç¿ÚÖ§³ÖPoEºÍPoE+
Õû»ú×î´ó¹¦ºÄ 40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£©
40W£¨²»´øPoE¸ºÔØ£©
460W£¨PoEÂúÔØ£©
»·¾³Óë¿¿µÃסÐÔ
µçÉÈ¼à¿Ø Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ
¹¤×÷ÎÂ¶È 0¡æ~50¡æ
´æ´¢ÎÂ¶È -40¡æ~70¡æ
¹¤×÷ʪ¶È 10%~90%RH
´æ´¢Êª¶È 5%~95%RH
¹¤×÷º£°Î -500m~5000m
·ÀÀ× 10kV

Èí¼þ¹æ¸ñ

Èí¼þ¹æ¸ñ RG-S2910-24GT4SFP-UP-H RG-S2910-24GT4XS-UP-H
VLAN Ö§³Ö4K VLAN
Ö§³ÖPort based VLAN
Ö§³ÖMAC based VLAN
Ö§³ÖProtocol based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖVoice VLAN
Ö§³ÖIP subnet-based VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
ACL Ö§³ÖIP³ß¶ÈIP ACL
Ö§³ÖIPÀ©´óIP ACL
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³Öר¼Ò¼¶ACL£¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
Ö§³ÖÈ«¾ÖACL
Ö§³ÖACL³Á¶¨Ïò
QoS Ö§³Ö»ùÓÚÈë¿Ú/³ö¿ÚµÄ¶Ë¿ÚÏÞ¿ì
Ö§³ÖÈë¿Ú/³ö¿Ú»ùÓÚÁ÷µÄÏÞ¿ì
Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WFQ¡¢SP+WRR¡¢SP+DRR¡¢RED/WRED¶ÓÁе÷¶È
Mirror Ö§³Öͨ³£ÒµÎñ¿Ú¡¢¾ÛºÏ¶Ë¿Ú×÷Ϊ¾µÏñµÄÔ´ÒÔ¼°Ö÷ÕŶ˿Ú
Ö§³ÖÒ»¶ÔÒ»¡¢Ò»¶Ô¶à¡¢¶à¶ÔÒ»ºÍ»ùÓÚÁ÷µÄ±¾µØ¡¢Ô¶³Ì¾µÏñ
Ö§³ÖRSPAN¡¢ERSPAN
Ö§³Ö¿çÉ豸µÄÁ÷Á¿¾µÏñ
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
L2 ºÍ̸ IEEE 802.3¡¢IEEE 802.3u¡¢IEEE 802.3z ¡¢IEEE 802.3x¡¢IEEE 802.3ad¡¢IEEE 802.1p¡¢IEEE 802.1x¡¢IEEE 802.3ab¡¢IEEE 802.1Q (GVRP)¡¢IEEE 802.1d¡¢IEEE 802.1w¡¢IEEE 802.1s¡¢IGMP Snooping v1/v2
°²È«¸öÐÔ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³Ö¿ÉÐÅÀµARP
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥/¶à²¥·ç±©ÒÖÔì
Ö§³Öδ³ÛÃûµ¥²¥ÒÖÔ죬×é²¥´ø¿íÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî± £»¤
Ö§³ÖRADIUSºÍTACACS+
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£©
Ö§³ÖSSH ºÍ SSH V2.0
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú± £»¤
ÏßÀ¼ì²â Ö§³ÖÏßÀ¼ì²â
EEE Ö§³ÖIEEE 802.3az ³ß¶ÈµÄ EEE½ÚÄܼ¼Êõ£ºµ±EEEʹÄÜʱ£¬´Ó¶ø´ó·ù¶ÈµÄ¼õÓ×¶Ë¿ÚÔڸý׶εŦºÄ£¬´ïµ½Á˽ÚÄܵÄÖ÷ÕÅ¡£
¶Ë¿ÚÐÝÃß Ö§³Ö¶Ë¿ÚÐÝÃß
PoE ¹©µçÉè¼ÆÖ§³ÖIEEE 802.3af¡¢IEEE 802.3at
Ö§³Ö×Ô¶¯¡¢½ÚÄܹ©µçÖÎÀíģʽ
Ö§³ÖÈÈÆô¶¯²»¼ä¶Ï¹©µç
Ö§³Ö¶Ë¿ÚÓÅÏȼ¶
Ö§³Ö¼æÈݷdz߶ÈPDÉ豸
Ö§³Ö¶ÔPoE¶Ë¿Ú°´Ê±¸ßµÍµç
IP·ÓÉ IPv4/IPv6 ¾²Ì¬Â·ÓÉ
RIP¡¢RIPng¡¢OSPFv2¡¢OSPFv3
Routing Policy
IPv6
»ù´¡ºÍ̸
IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢IPv6 ACL¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ
VSU¸öÐÔ Ö§³ÖVSUÐé¹¹»¯¼¼Êõ
Ö§³Ö±¾µØ¶ÑµþºÍÔ¶³Ì¶Ñµþ
Ö§³Ö¶ÑµþÄÚ¿ç»úÏäµÄÁ´Â·°ó¸¿
ÁãÅäÖà ֧³ÖCWMP(TR069)ºÍ̸³ß¶ÈºÍ̸
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog/Debug¡¢NTP/SNTP¡¢FTP¡¢TFTP¡¢Web¡¢sFLOW
·¢Õ¹¾ßÌå²ÎÊý

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÀûÓð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
¹¦ºÄ(1)
µçÔ´(2)
Èý²ã»¥»»»ú(1)
¶¨Ãû¹æ¶¨(1)
¶Ë¿Ú¾ÛºÏ(1)
»·Â·¼ì²â(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
¸Ã¿î»¥»»»úÊǼ¸²ã»¥»»»ú£¿
ÓÐЧ 138 ÎÞÓà 19

Èý²ãµÄ£¬RG-S2910XS-E¡¢RG-S2910-H¡¢RG-S2910G-P¡¢RG-S2910V2¡¢RG-S2910-LµÈϵÁл¥»»»ú¶¼ÊÇÈý²ã»¥»»»ú¡£

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S2910-24GT4SFP-UP-H¡¢RG-S2910-24GT4XS-UP-H¡¢RG-S2910C-48GT2XS-P-E¡¢RG-S2910-48GT4XS-EÊÇ·ñÖ§³ÖµçÔ´ÈßÓࣿ
ÓÐЧ 72 ÎÞÓà 5

RG-S2910C-48GT2XS-HP-E»¥»»»úµçÔ´Ö§³ÖÁ½¸öµçÔ´Ä£¿é¹¤×÷£¬ÈôÊǵ¥µçÔ´Ä£¿é¹¦ÂÊ´óÓÚ¹¤×÷¹¦ÂÊÔòÄܹ»ÈßÓ࣬ÆäËûÈý¿î²»Ö§³ÖÈßÓà¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Ò飿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌ⣬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿