GA»Æ½ð¼×

¡°¼«¼ò¡±»ÀР¡¤ È«ÓòÖÇÁª Ø­ GA»Æ½ð¼×м«¼òÁ캽ÏÂÒ»´úÐ£Ô°Íø½¨Éè×êÑлá
date
Ô¤Ô¼Ö±²¥
ÎÞ¸Ð×¼Èë ÈËÎïͳ¹Ü Ø­ RG-SAM+5.X ÐÂÒ»´ú¸ßУAIÈÏ֤ƽ̨°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
RG-S7810E
RG-S7810E
RG-S7810E
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

RG-S7810E

RG-S7810E

ÀàÐÍ£º

²úÆ·¸öÐÔ£º

µ±¼´Õ÷ѯ

ÔÆ¼Ü¹¹ÍøÂçÖ÷Ìâ £¬¸ß¼¶ÅäÖÃ

¸ß»úÄÜÂú×㽫À´Ê®ÄêÍøÂç·¢Õ¹

RG-S7800EϵÁÐÖ§³ÖÒµ½ç¸ß»úÄܵÄÓ×°üÏß¿ìת·¢ÄÜÁ¦ £¬Ô̺¬¸ßÃܶȰ忨ÔÚÄÚµÄËùÓа忨¾ù¿ÉʵÏÖ64×Ö½ÚÓ×°üÏß¿ìת·¢ £¬´ÓÈÝÓ¦¶Ô½«À´ÍøÂç¶Ô¸ß¿ìת·¢²»¶ª°üµÄ¿Ì±¡ÐèÒª¡£

Ðé¹¹»¯ÈÃ×ÊÔ´°´Ðè·ÖÅä

Ðé¹¹»¥»»µ¥ÔªVSU3.0

RG- S7800EϵÁÐÖ§³ÖÒµ½ç³¬Ç°µÄVSU3.0£¨Virtual Switching Unit £¬Ðé¹¹»¥»»µ¥Ôª£©Ðé¹¹»¯¼¼Êõ £¬½«¶ą̀ÎïÀíÉ豸Ðé¹¹»¯ÎªÒ»Ì¨Âß¼­É豸 £¬Í³Ò»ÔËÐÐÖÎÀí £¬´ó·ùÏ÷¼õÍøÂç½Úµã £¬½µµÍÍøÂçÔËάÖÎÀíÈËÔ±¹¤×÷Á¿¡£Ôö³¤ÍøÂç¿¿µÃס ÐÔ £¬ÊµÏÖ50~200msÁ´Â·¹ÊÕϼ±¾çÇл» £¬±£¾þÇͺ¦ÒµÎñ²»Öжϴ«Êä¡£Ö§³Ö¿çÉ豸Á´Â·¾ÛºÏ £¬·½±ã½ÓÈë·þÎñÆ÷/»¥»»»úʵÏÖË«»îÁ´Â·ÉÏÁª £¬ÍøÂçÓÐЧÏνӴø¿í³É ±¾Ôö³¤¡£

Ðé¹¹»¥»»É豸VSD

RG- S7800EϵÁÐͨ¹ýVSD£¨Virtual Switch Device £¬Ðé¹¹»¥»»É豸£©¼¼Êõ¿É½«Ò»Ì¨É豸Ðé¹¹»¯Îª¶ą̀Ðé¹¹É豸 £¬Ã¿Ì¨Ðé¹¹É豸ӵÓжÀÁ¢µÄÅäÖÃÖÎÀí½çÃæ¡¢¶ÀÁ¢Ó²¼þ×ÊÔ´·ÖÅä(ºÃ±ÈÄÚ´æ¡¢TCAM¡¢Ó²¼þ ת°ä·¢) £¬Äܹ»¶ÀÁ¢³ÁÆô¶ø²»Ó°ÏìÆäËüµÄÐé¹¹»¥»»»ú¡£ÓÐЧΪÄúʵÏÖÍøÂç×ÊÔ´µÄ°´Ðè·ÖÅä £¬¿ÉÈÃÖ÷Ì⻥»»»ú×ÊԴͬʱ¹²Ïí¸ø¶à¸öÇøÓò»òÓû§Ê¹Óá£

µçÐż¶µÄ¸ß¿¿µÃסÐÔÉè¼Æ

RG-S7800EϵÁи÷¹Ø¼ü²¿¼þ¾ùΪÈßÓàÉè¼Æ£ºÖ÷¿ØÒýÇæ1+1ÈßÓà £¬µçÉÈN+MÈßÓà £¬µçÔ´Ä £¿éN+MÈßÓà £¬Í¬Ê±¸÷ÈßÓà×é¼þ¾ùÖ§³ÖÈȲå°Î £¬ÓÐЧÌá¸ßÕû»úµÄ¿¿µÃסÐԺͿÉÓÃÐÔ¡£

Ö§³ÖÈȲ¹¶¡ºÍISSU¼¼Êõ £¬¿ÉʵÏÖÉ豸ÔÚÏß½øÐв¹¶¡Éý¼¶¡£

Ö§³ÖGR for OSPF/IS-IS/BGPµÈ £¬Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓɵÈ £¬ÊµÏÖ¸÷ºÍ̸µÄ¼±¾ç¹ÊÕϼì²â»úÔì £¬¹ÊÕϼì²â¹¦·òÓ×ÓÚ50ms¡£

¶à¹ý³ÌÄ £¿é»¯²Ù×÷ϵͳ

´Ó 1998ÄêÆð £¬GA»Æ½ð¼×ÍøÂç¾ÍÆðÍ·ÁËÄ £¿é»¯²Ù×÷ϵͳµÄÑз¢Í¶Èë £¬RG-S7800EϵÁÐÈí¼þƽ̨»ùÓÚÐÂÒ»´úµÄRGOS 11.X¶à¹ý³ÌÄ £¿é»¯²Ù×÷ϵͳ £¬½«ËÉñîºÏµÄ·À»ðǽ¡¢ÎÞÏß¡¢IPFIX¡¢ÈÏÖ¤µÈÒµÎñ¸öÐԹ鲢µ½Í³Ò»ÔƼܹ¹ÍøÂç²Ù×÷ϵͳƽ̨ £¬Ö§³ÖÐé¹¹»¯ÄÜÁ¦ºÍ·á˶µÄÊý ¾ÝÖÐÐĺÍÔ°ÇøÍø¸öÐÔ¡£ÔÚ¶à¹ý³ÌÄ £¿é»¯¡¢¹ý³Ì±¸·Ý¡¢ÈȲ¹¶¡µÈ¹Ø¼ü¿ÉÓÃÐÔÖ¸±êÉÏ´ïµ½Òµ½çµ±ÏÈˮƽ¡£

¸ßЧµÄÂÌÉ«½ÚÄÜ

RG-S7800EϵÁÐѡȡ40nmоƬ¹¤ÒÕ £¬Ïà±È´«Í³90nmºÍ65nm¹¤ÒÕ¸ü½ÚÄÜ¡£

ÄÚ²¿ÏµÍ³µÍѹ¹©µçÉè¼Æ £¬¸ßЧÄÜÄ £¿é»¯µçÔ´ £¬¹©µçϵͳЧÄܸü¸ß¡£

¶àºËCPUÖ§³Ö¶¯Ì¬¹¦ºÄÖÎÀí £¬È«Êý¹â¿ÚѡȡÎÞPHYÉè¼Æ £¬½µµÍ¹â¿Ú¹¦ºÄ £¬È«ÊýÒÔÌ«Íøµç¿ÚÖ§³ÖEEE¸ßЧ½ÚÄܳ߶È £¬µÍ¸ºÔØÊ±¿É½ÚÔ¼¹¦ºÄ¡£

ÖÇÄܵçÉÈÖ§³Ö256¼¶µ÷¿ì £¬¾«ÃÜοØ £¬½ÚÄܽµÔë £»¸ßÎÂÏ¿ɳ־ù¤×÷ £¬ÊÊÓ¦¶ñÁÓ»·¾³ £¬ÎªÄú´ó·ù¶È½µµÍÄܺÄ¡£

¼¼Êõ²ÎÊý

¼¼Êõ²ÎÊý

²ÎÊýÃèÊö

²úÆ·ÐͺÅ

RG-S7805E

RG-S7807E

RG-S7810E

Ä £¿é²å²Û

5¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ £¿é£©

7¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ £¿é£©

10¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ £¿é£©

»¥»»ÈÝÁ¿

4.8Tbps/12Tbps

8Tbps/20Tbps

12.8Tbps/32Tbps

°üת·¢¿ìÂÊ

1,440Mpps/5,400Mpps

2,400Mpps/9,000Mpps

3,840Mpps/14,400Mpps

É豸Ðé¹¹»¯

Ö§³ÖVSU3.0(Virtual Switching Unit,Ðé¹¹»¥»»µ¥Ôª)

Ö§³ÖVSD(Virtual Switch Device,Ðé¹¹»¥»»É豸)

SDN

Ö§³ÖOpenFlow 1.3

L2 ¸öÐÔ

Ö§³ÖJumbo Frame

Ö§³Ö802.1Q

Ö§³ÖSTP¡¢RSTP¡¢MSTP

Ö§³ÖSuper VLAN

Ö§³ÖGVRP

Ö§³ÖQinQ¡¢½Ã½ÝQinQ¡¢QinQÖÕ½á

Ö§³ÖLLDP

IPv4 ¸öÐÔ

Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIP¡¢OSPF¡¢IS-IS¡¢BGP4

Ö§³ÖVRRP

Ö§³ÖµÈ¼Û·ÓÉ

Ö§³ÖÕ½Êõ·ÓÉ

Ö§³ÖGREËí·

IPv6 ¸öÐÔ

Ö§³Ö¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+¡¢IS-ISv6¡¢MLDv1/v2

Ö§³ÖVRRPv3

Ö§³ÖµÈ¼Û·ÓÉ

Ö§³ÖÕ½Êõ·ÓÉ

Ö§³ÖÊÖ¹¤Ëí·¡¢×Ô¶¯Ëí·¡¢ISATAPËí·¡¢Ö§³ÖGREËí·µÈ

×é²¥

Ö§³ÖIGMP v1,v2,v3

Ö§³ÖIGMP Snooping

Ö§³ÖIGMP Proxy

Ö§³ÖPIM-DM¡¢PIM-SM¡¢PIM-SSMµÈ×鲥·ÓɺÍ̸

Ö§³ÖMLD

Ö§³Ö×é²¥¾²Ì¬Â·ÓÉ

MPLS

Ö§³ÖMPLSת·¢

Ö§³ÖMPLS VPN/VPLS

Ö§³ÖVPWS

ACL

Ö§³Ö³ß¶È¡¢À©´ó¡¢×¨¼Ò¼¶ACL

Ö§³ÖACL 80

Ö§³ÖIPv6 ACL

QoS

Ö§³Ö802.1P

Ö§³ÖSP¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRRµÈ¶ÓÁе÷¶È»úÔì

Ö§³ÖRED/WRED

Ö§³Ö»ùÓÚ³ö¶Ë¿Ú/Èë¶Ë¿ÚµÄÏÞ¿ì

Ö§³ÖHQoS

PoE

Ö§³ÖÅäÖÃPoEÏß¿¨ £¬²¢ÓɶÀÁ¢PoEµçÔ´²Û¹©µç £¬Ô¤·ÀÒòPoE¹©µç¶øÓ°ÏìÆäËûÒµÎñÄ £¿é¹©µç²»±äÐÔ

¿¿µÃסÐÔ

¶ÀÁ¢µÄ»¥»»Íø°åÓë¶ÀÁ¢µÄÖ÷¿Ø°åÉè¼Æ £¬ÊµÏÖת·¢Óë½ÚÔìÆ½ÃæÆëÈ«·ÖÀë

Ö÷¿Ø°åÖ§³Ö1+1ÈßÓ౸·Ý

µçÔ´¡¢µçÉÈÖ§³ÖN+MÈßÓ౸·Ý

±³°åÎÞÔ´Éè¼Æ £¬Ô¤·Àµ¥µã¹ÊÕÏ

¸÷×é¼þÖ§³ÖÈȲå°Î

Ö§³ÖÈȲ¹¶¡Ö°ÄÜ £¬¿ÉÔÚÏß½øÐв¹¶¡Éý¼¶

Ö§³ÖISSU

Ö§³ÖGR for OSPF/IS-IS/BGP

Ö§³ÖBFD for VRRP/OSPF/BGP4/ISIS/ISISv6/MPLS/¾²Ì¬Â·ÓɵÈ

°²È«ÐÔ

Ö§³ÖNFPP£¨»ù´¡°²È«± £»¤Õ½Êõ£©

Ö§³ÖCPP£¨CPU± £»¤£©

Ö§³ÖDAI £¬¶Ë¿Ú°²È« £¬IP Source Guard

Ö§³Ö802.1x/Portal/MacµÈ¶àÖÖÈÏÖ¤·½Ê½

Ö§³ÖRADIUSºÍTACACS+Óû§µÇ¼ÈÏÖ¤

Ö§³ÖuRPF

Ö§³ÖµÇ¼ÈÏÖ¤¡¢¿ÚÁȫ

Ö§³Öδ֪×é²¥²»ËÍCPU¡¢Ö§³Öδ֪µ¥²¥ÒÖÔì

Ö§³ÖSSHv2 £¬ÎªÓû§µÇ¼Ìṩ°²È«¼ÓÃÜͨ·

ÖÎÀíÐÔ

Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ºÅÁîÐÐÅäÖÃ

Ö§³ÖFTP¡¢TFTP¡¢XmodemÎļþ¸ßµÍÔØÖÎÀí

Ö§³ÖSNMP V1/V2c/V3

Ö§³ÖRMON

Ö§³ÖNTPʱÖÓ

Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô¸´Ô­

Ö§³Öϵͳ¹¤×÷ÈÕÖ¾

Ö§³ÖsFLOWÁ÷Á¿·ÖÎö

³ß´ç£¨¿íxÉîx¸ß£©(mm)

442 x 595 x 219.5(5U)

442 x 595 x 352.8(8U)

442 x 821 x 797.3(18U)

µçÔ´

RG-PA1600I£º90~180V¹¦ÂÊ£º1200W £»180~264V¹¦ÂÊ£º1600W

RG-PA600I£º90~180V¹¦ÂÊ£º600W £»180~264V¹¦ÂÊ£º600W

RG-PD1600I£º-40.5V~ -75V¹¦ÂÊ£º1400W

RG-PD600I£º-40.5V~ -75V¹¦ÂÊ£º600W

RG-PA1600I-PL£º90~175V¹¦ÂÊ£º1000W £»176~264V¹¦ÂÊ£º1600W

RG-PA3000I-PL£º90~175V¹¦ÂÊ£º2000W £»176~209V¹¦ÂÊ£º2500W £»210~264V¹¦ÂÊ£º3000W

MTBF

> 200,000 Ó×ʱ

ζÈ

¹¤×÷ζȣº0¡æ  µ½ 50¡æ

´æ´¢Î¶ȣº-40¡æ µ½ 70¡æ

ʪ¶È

¹¤×÷ʪ¶È£º10% µ½ 90% RH£¨ÎÞÀäÄý£©

´æ´¢Êª¶È£º5% µ½ 95% RH

¹¤×÷¸ß¶È/º£°Î

-500~5000M

 

·¢Õ¹¾ßÌå²ÎÊý

×ÊÔ´ÖÐÐÄ

ÀûÓð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

faq-none
ÔÝÎÞÎÊÌâ £¬ÎÒÒªÌáÎÊ
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ £¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖà £¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
ev-close
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ £¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
Äú²»ÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
ev-close
ÄúÊÇ·ñ»¹ÓÐÆäËûÎÊÌâ»ò½¨Òé £¿
ΪÁ˼±¾ç½â¾ö²¢»Ø¸´ÄúµÄÎÊÌâ £¬ÄúÄܹ»ÁôÏÂÁªÏµ·½Ê½
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿