GA»Æ½ð¼×

´Ó³ß¶Èµ½Â䵨£ºÍòÕ×Ô°Çø £¬Ñ¡ÒÔÌ«²Ê¹â Ø­ ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹â×êÑл㱨¡·¼¼Êõ×êÑлá
date
Ô¤Ô¼Ö±²¥
AIʱÆÚ £¬Ò½ÁÆÍøÂçÔõô½¨ Ø­ GA»Æ½ð¼×Ò½ÁƼ«¼òÒÔÌ«²Ê¹âË«³¬ÈÚºÏÍøÂç½â¾ö¹æ»®°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

Äú¶©ÔĵIJúÆ·ÓиüР£¬Çëʵʱ²éÔÄ

²é¿´ÏêÇé
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48GT4XS-HP-X
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

48¿ÚǧÕ×µçÈý²ãÆóÒµ¼¶Ö÷Ìâ»ã¾ÛÍøÂçPoE»¥»»»ú £¬4¸öÍòÕ×ÉÏÐпÚ £¬RG-S5760C-48GT4XS-HP-X

ÓÃÓÚ´óÐÍÍøÂç»ã¾Û¡¢ÖÐÓ×ÐÍÍøÂçÖ÷Ìâ

²úÆ·¸öÐÔ£º

  • ¶Ë¿ÚÀàÐÍ·á˶ £¬48¸öǧÕ×ÒÔÌ«Íø¿Ú £¬Ö§³ÖPoE/PoE+ £¬4¸ö10G¹â¿ÚÓÃÓÚÉÏÁª £¬4MB»º´æ
  • Ó²¼þ¼¶¶à³Á± £»¤ £¬±£ÏÕÉ豸³ÖÐøÔËÐÐ £¬ÍøÂç²»±ä²»µôÏß
  • Ö§³ÖVSUÐé¹¹»¯¼¼Êõ £¬½Ã½Ý×éÍø»úÄÜÇ¿
  • Èý²ã·ÓɺÍ̸°Ñ¿Ø £¬ÊÊÅä¶à³ÁÒµÎñ £¬ÐÅÏ¢´«Êä¸ßЧÓб£ÏÕ
  • ÍøÂ簲ȫʵʱ¼à²â £¬Ö§³ÖCPP¡¢NFPP £¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ
  • Ö§³ÖSNMP¡¢RMON¡¢Syslog¡¢USB¸öÐÔ¼°CLI¡¢WebÍø¹Ü¡¢TelnetµÈ¶à³ÁÖÎÀí·½Ê½ £¬Ò×ÊØ»¤
µ±¼´Õ÷ѯ
Èí¼þºÍ̸
point1
¸ß¿¿µÃסÐÔ
VRRP
GR for RIP/OSPF/BGPµÈ
RLDP
REUP
ERPS
BFD
VSU£¨Ðé¹¹»¯¼¼Êõ
point2
Èý²ã·ÓɺÍ̸
Ö§³Ö¾²Ì¬ºÚ¶´Â·ÓÉ
RIP
RIPng
OSPFv2
OSPFv3
BGP4
BGP4+
IS-IS
Routing Policy
point3
ÀûÓúÍ̸
DNS
DHCP Relay
DHCP Server
DHCP Client
Telnet
TFTP
FTP
NTP
SNTP
point4
ÖÎÀí¸öÐÔ
SNMPv1/v2c/v3
CLI(Telnet/Console)
RMON(1 £¬2 £¬3 £¬9)
Web
Syslog/Debug
GRPC
point5
°²È«¸öÐÔ
Ö§³ÖCPP¡¢NFPP
Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞ¿ì
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî± £»¤
Ö§³ÖRADIUS ºÍ TACACS+
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤
Ö§³ÖSSH
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard

Èý²ãǧÕ×Ö÷Ìâ&»ã¾Û»¥»»»ú RG-S5760C-48GT4XS-HP-X

¿ÉÓÃÓÚÖÐÓ×ÐÍÔ°ÇøÍøÂç»ã¾ÛÉ豸 £¬4¸öÍòÕ×ÉÏÐйâ¿Ú´«ÊäÊý¾Ý £»48¸öǧÕ××ÔÊÊÓ¦ÒÔÌ«Íø¿Ú £¬Ö§³ÖPoE/PoE+ £¬Îª½ü¾àÀëÒµÎñÌṩ¸ß¿ìÓÃÍøÂÄÀú
¿ÉÓÃÓÚÖÐÓׯóÒµÖ÷ÌâÉ豸 £¬¾ß±¸¸ßÀ©´ó £¬¸ßЧÐÔ £¬¿ÉÖÎÀíÐÔ £¬É豸¼¶ÓëÁ´Â·¼¶¶à³Á¿¿µÃסÐÔ £¬Ìṩ²»±äµÄÍøÂç»úÄÜ

Ó²¼þ¼¶¶à³Á± £»¤ £¬±£ÏÕÉ豸³ÖÐøÔËÐÐ £¬ÍøÂç²»±ä²»µôÏß

Ó²¼þ¼¶Ë«BOOT
ÈȲå°ÎÈßÓàµçÔ´
ѡȡÁ½¸öFLASHоƬ´æ´¢BOOTÈí¼þ£¨ÏµÍ³Êèµ¼·¨Ê½£© £¬ÊµÏÖÓ²¼þ¼¶BOOTÈßÓ౸·Ý £¬Ô¤·ÀÒòFLASHоƬ¹ÊÕϵ¼Ö»¥»»»úÎÞ·¨Æô¶¯

Ö§³ÖVSUÐé¹¹»¯¼¼Êõ £¬½Ã½Ý×éÍø»úÄÜÇ¿

ºÁÃë¼¶¹ÊÕϸ´Ô­
¸ßÀ©´ó
¼ò»¯×éÍø
VSUÐ鹹ϵͳºÍ±íΧÉ豸ͨ¹ý¾ÛºÏÁ´Â·ÏνÓÈçÓö¹ÊÕÏ £¬¿ÉºÁÃë¼¶Çл»Á´Â· £¬±£ÕÏÍøÂç²»¼ä¶Ï

Èý²ã·ÓÉÖ°ÄܰѿØ £¬ÊÊÅä¶à³ÁÒµÎñ £¬ÐÅÏ¢´«Êä¸ßЧÓб£ÏÕ

IPV4¡¢IPV6ºÍ̸
·á˶µÄ×é²¥ºÍ̸
¾²Ì¬¡¢¶¯Ì¬Â·ÓÉ
Ó²¼þÖ§³ÖË«ºÍ̸ջÐÅÏ¢¸ß¿ì»¥»» £¬Âú×ã´ÓÔ°ÇøIPV4µ½IPV6µÄÍøÂç¹ý¶É £¬µØÖ·ÈÝÁ¿ÓëÍøÂ簲ȫ´ó´óÌáÉý

¶àÖÖÍøÂ簲ȫսÊõ £¬ÊµÊ±¼à²â £¬±£ÕÏÍøÂç³ÖÐø×³ÊµÐÔ

CPP± £»¤Õ½Êõ
NFPP± £»¤Õ½Êõ
´óÁ¿¡¢ÔÓÂÒÊý¾ÝÏȾ­¹ýCPP´¦Öà £¬Ô¤·ÀÖ±½Ó¹¥»÷µ½CPU £¬±£ÕÏCPU¸ßÔËÐÐϵIJ»±äÐÔ £¬ÓÐЧÌá¸ßÉ豸µÄ°²È«»úÄÜ

¶à³ÁÍøÂçÖÎÀí·½Ê½ ʵÏÖµ¥Ò»ÇáËɵÄÍøÂçÊØ»¤

ÖÎÀí¸öÐÔ
ÖÎÀí·½Ê½
¶ą̀É豸ÖÎÀí
Ö§³ÖRMON¡¢Syslog¡¢USB±¸·ÝÈÕÖ¾¸öÐÔ £¬±£ÏÕÈÕ³£ÓÃÍøµÄÕý³£Õï¶ÏÓëÊØ»¤

¼¼Êõ²ÎÊý

Ó²¼þ¹æ¸ñ

¸ù»ù¸öÐÔ

¸ù»ù¸öÐÔ RG-S5760C-24GT8XS-X RG-S5760C-24SFP/8GT8XS-X RG-S5760C-48GT4XS-X RG-S5760C-48GT4XS-HP-X RG-S5760C-48SFP4XS-X
¹Ì¶¨¶Ë¿Ú 24¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬8¸ö1G/10G SFP+¹â¿Ú £¬ 2¸öÄ£¿é»¯µçÔ´²å²Û 24¸ö1000M SFP¹â½Ó¿Ú£¨1-16¿ÚΪ100M/1000M SFP¹â½Ó¿Ú£© £¬8¸ö¸´ÓõÄ10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬8¸ö1G/10G SFP+¹â¿Ú £¬2¸öÄ£¿é»¯µçÔ´²å²Û 48¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö1G/10G SFP+¹â¿Ú £¬2¸öÄ£¿é»¯µçÔ´²å²Û 48¸ö10/100/1000M×ÔÊÊÓ¦µç¿Ú £¬4¸ö1G/10G SFP+¹â¿Ú £¬2¸öÄ£¿é»¯µçÔ´²å²Û £»Ö§³ÖPoE/PoE+ 48¸ö1000M SFP¹â½Ó¿Ú £¬4¸ö1G/10G SFP+¹â¿Ú £¬3¸öÄ£¿é»¯µçÉÈ £¬2¸öÄ£¿é»¯µçÔ´²å²Û
ÖÎÀí¿Ú 1¸öMGMT¶Ë¿Ú¡¢1¸öConsole¶Ë¿Ú¡¢1¸öUSB¶Ë¿Ú £¬ÇкÏUSB2.0µÄ³ß¶È
À©´ó²Û 1¸öÀ©´ó²å²Û £¬¿ÉÓÃÓÚÀ©´óÒµÎñ°å¿¨ £¬Ô¤Áô1¸öÀ©´ó²å²Û £¬ÓÃÓÚÀ©´óÖÎÀí°å¿¨

V1.XX&2.XXÓ²¼þ°æ±¾£º1¸öÀ©´ó²å²Û £¬¿ÉÓÃÓÚÀ©´óÒµÎñ°å¿¨ £¬Ô¤Áô1¸öÀ©´ó²å²Û £¬ÓÃÓÚÀ©´óÖÎÀí°å¿¨

V3.XXÓ²¼þ°æ±¾£º1¸öÀ©´ó²å²Û £¬¿ÉÓÃÓÚÀ©´óÒµÎñ°å¿¨

1¸öÀ©´ó²å²Û

»¥»»ÈÝÁ¿ 2.56Tbps/25.6Tbps
°üת·¢ÂÊ 660Mpps/930Mpps
¹¦ºÄ(Âú¸ººÉʱ)£º <60W (²»´øÀ©´ó¿¨)
<85W£¨´øÀ©´ó¿¨£©
<77W (²»´øÀ©´ó¿¨)
<102W£¨´øÀ©´ó¿¨£©
<70W (²»´øÀ©´ó¿¨)
<95W£¨´øÀ©´ó¿¨£©
Õû»ú¹¦ºÄ <120W
Âú¸ºÔع¦ºÄ < 1600W
<105W£¨²»´øÀ©´ó¿¨£©
<125W£¨´øÀ©´ó¿¨£©
²úÆ·³ß´ç£¨¿í×Éî׸ߣ© 440mm x 340mm x 44mm 440mm x 340mm x 44mm V1.XX&2.XXÓ²¼þ°æ±¾£º440mm x 340mm x 44mm
V3.XXÓ²¼þ°æ±¾£º442mm x 420mm x 43.6mm
442.0mm x 420.0mm x 43.6mm 442.0mm x 420.0mm x 43.6mm

ÎïÀí¸öÐÔ

ÎïÀí¸öÐÔ RG-S5760C-24GT8XS-X RG-S5760C-24SFP/8GT8XS-X RG-S5760C-48GT4XS-X RG-S5760C-48GT4XS-HP-X RG-S5760C-48SFP4XS-X
µçÔ´ ·ÇPOEÐͺŻ¥»»£¨AC£©ÊäÈë
  • ¶î¶¨µçѹÁìÓò£º100V-240V

  • ×î´óµçѹÁìÓò£º90V~264V

  • ƵÂÊ£º50/60Hz

¸ßѹֱÁ÷(HVDC)ÊäÈë
  • ¶î¶¨µçѹÁìÓò£º240V

  • ×î´óµçѹÁìÓò£º192~288V

PoEÐͺŻ¥»»£¨AC£©ÊäÈë
  • ¶î¶¨µçѹÁìÓò£º200V-240V

  • ×î´óµçѹÁìÓò£º176V~264V

  • ƵÂÊ£º50/60Hz

  • µÍѹֱÁ÷£¨LVDC£©ÊäÈë

  • ¶î¶¨µçѹÁìÓò£º-48~-60VDC

  • ×î´óÊäÈëµçѹ£º-36~-75VDC
µçÉÈ ÄÚÖÃ3µçÉÈ£¨V3.XXÓ²¼þ°æ±¾RG-S5760C-48GT4XS-X£ºÄÚÖÃ2µçÉÈ£©
Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ

Ä£¿é»¯2µçÉÈ

Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ

Ä£¿é»¯3µçÉÈ

Ö§³ÖµçÉȵ÷¿ì¼°µçÉȹÊÕϸ澯ְÄÜ

É¢ÈÈ V1.XX/V2.XXÓ²¼þ°æ±¾£º×óÓÒ·ç·
V3.XXÓ²¼þ°æ±¾RG-S5760C-48GT4XS-X£ºÇ°ºó·ç·

ǰºó·ç·

ǰºó·ç·

ζȸ澯 Ö§³Öζȸ澯ְÄÜ
ÎÂ¶È ¹¤×÷ζȣº0¡æ~45¡æ
´æ´¢Î¶ȣº-40¡æ~70¡æ
ʪ¶È ¹¤×÷ʪ¶È£º10%~90%£¨ÎÞÄý¶£©
´æ´¢Êª¶È£º5%~95%
ͨѶ½Ó¿Ú·ÀÀ× ÒµÎñ½Ó¿Ú£º10KV

Èí¼þ¹æ¸ñ

²úÆ·¸öÐÔ RG-S5760C-24GT8XS-X RG-S5760C-24SFP/8GT8XS-X RG-S5760C-48GT4XS-X
RG-S5760C-48GT4XS-HP-X
RG-S5760C-48SFP4XS-X
VLAN Ö§³Ö4K 802.1Q VLAN
Ö§³ÖPort based VLAN
Ö§³ÖPrivate VLAN
Ö§³ÖºÍ̸VLAN
Ö§³ÖIP×ÓÍøVLAN
Ö§³ÖVoice VLAN
Ö§³ÖGVRP
QinQ Ö§³Ö¸ù»ùQinQ
Ö§³Ö½Ã½ÝQinQ
Á´Â·¾ÛºÏ Ö§³ÖLACP(802.3ad)
ÌìÉúÊ÷ Ö§³ÖSTP¡¢RSTP¡¢MSTP
VxLAN Ö§³ÖVXLAN¶þ²ãÍøÇÅ
Ö§³ÖVXLANÈý²ãÍø¹Ø
Ö§³ÖEVPN VXLAN
DHCP Ö§³ÖDHCP Server
Ö§³ÖDHCP Client
Ö§³ÖDHCP Snooping
Ö§³ÖDHCP Relay
Ö§³ÖIPv6 DHCP Server
Ö§³ÖIPv6 DHCP Snooping
Ö§³ÖIPv6 DHCP Client
Ö§³ÖIPv6 DHCP Relay
IPv6»ù´¡ºÍ̸ IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢ICMPv6¡¢ÎÞ״̬×Ô¶¯ÅäÖá¢Path MTU Discovery
IP·ÓÉ Ö§³Ö¾²Ì¬Â·ÓÉ
Ö§³ÖRIP £¬RIPng
Ö§³ÖOSPFv2 £¬OSPFv3 £¬IS-ISv4 £¬IS-ISv6
Ö§³ÖBGP4 £¬BGP4+
Ö§³ÖµÈ¼Û·ÓÉ
Ö§³Ö»ùÓÚ°üµÄ¸ºÔØÆ½ºâºÍ»ùÓÚÁ÷µÄ¸ºÔØÆ½ºâ
Ö§³ÖMCE
×é²¥ Ö§³ÖIGMP v1 £¬v2 £¬v3 £¬IGMP ´úÀí
Ö§³ÖIGMP v1 £¬v2ºÍv3 Snooping
Ö§³ÖIGMP¹ýÂË £¬IGMP¼±¾çÍÑÀë
Ö§³ÖPIM-DM £¬PIM-SM £¬PIM-SSM
Ö§³ÖMLD Snooping £¬MLD
Ö§³ÖPIM for IPv6
MPLS Ö§³ÖMPLS L3VPN
Ö§³ÖMCE £¬Ö§³ÖVRFÊýÁ¿512¸ö
ACL Ö§³Ö½Ã½Ý¶àÑùµÄÓ²¼þACL£º
Ö§³Ö³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£©
Ö§³ÖÀ©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£©
Ö§³ÖMACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©
Ö§³Ö»ùÓÚ¹¦·òACL
Ö§³Öר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£©
Ö§³ÖACL80
Ö§³ÖIPv6 ACL
QoS Ö§³Ö¶Ë¿ÚÁ÷Á¿¼ø±ð
Ö§³Ö¶Ë¿ÚÁ÷Á¿ÏÞ¿ì
Ö§³Ö802.1p/DSCP/ToSÁ÷Á¿·ÖÀà
ÿ¶Ë¿Ú8¸öÓÅÏȼ¶¶ÓÁÐ
Ö§³ÖSP¡¢DRR¡¢WRR¡¢SP+DRR¡¢SP+WRR¡¢RED/WRED¶ÓÁе÷¶È
°²È«¸öÐÔ Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨
¹ýÂË·¸·¨µÄMACµØÖ·
Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x
Ö§³ÖMAB
Ö§³ÖPortal ºÍPortal 2.0ÈÏÖ¤
Ö§³ÖARP-Check
Ö§³ÖDAI
Ö§³ÖARP±¨ÎÄÏÞ¿ì
Ö§³Ö·ÀÍø¹ØARPºýŪ
Ö§³Ö¹ã²¥·ç±©ÒÖÔì
ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî± £»¤
Ö§³ÖRADIUS ºÍ TACACS+
É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤
Ö§³ÖSSH
Ö§³ÖBPDU Guard
Ö§³ÖIP Source Guard
Ö§³ÖCPP¡¢NFPP
Ö§³Ö¶Ë¿Ú± £»¤
ÖÎÀí¸öÐÔ SNMP¡¢CLI(Telnet/Console)¡¢RMON¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢SNMP over IPv6¡¢IPv6 MIB support for SNMP ¡¢SSHv6¡¢Telnet v6¡¢FTP/TFTP v6¡¢DNS v6¡¢NTP for v6¡¢Traceroute v6
Ö§³ÖsFLOW £¬¿ÉÀûÓÃÊý¾ÝÁ÷Ëæ»ú²ÉÑù¼¼Êõ £¬¶Ô»¥»»»úµÄÁ÷Á¿½øÐÐÁ÷ÐÅÏ¢²ÉÑù
Ö§³ÖMACCŵ¿Í¹«ÓÐÔÆÆ½Ì¨ÖÎÀí
¸ß¿¿µÃסÐÔ Ö§³ÖVSU£¨Ðé¹¹»¯¼¼Êõ £¬½«¶ą̀É豸Ðé×é³É1̨£©¡¢Ö§³ÖGR for RIP/OSPF/BGPµÈ·ÓɺÍ̸¡¢Ö§³ÖBFD¼ì²â¡¢Ö§³ÖERPS£¨G.8032£©¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢µçÔ´Ä£¿éÖ§³ÖÈȲå°ÎÖ°ÄÜ
M-LAG
ÁãÅäÖà ֧³ÖCWMP(TR069)ºÍ̸³ß¶ÈºÍ̸
PoE ²»Ö§³Ö ²»Ö§³Ö RG-S5760C-48GT4XS-HP-XÖ§³Ö ²»Ö§³Ö
·¢Õ¹¾ßÌå²ÎÊý

ÀûÓôîÅä

ÍòÕ×Á´Â·
ÍÆ¼öÓÃÓÚÖÐÓ×ÐÍÆóÒµÔ°ÇøÍø £¬½ÌÓýÐ£Ô°Íø/³ÇÓòÍø £¬¿í´øÓ×ÇøÍøÂçµÈ»ã¾ÛÉ豸 £¬ÊµÏÖÍòÕ×»ã¾Ûµ½Ö÷ÌâµÄ¸ß»úÄÜ´ø¿íÁ´Â· £¬Âú×ã½ÓÈëÓû§ÐÅÏ¢Á¿ÈÕÒæÔö³¤µÄ±ØÒª
match1
ÍÆ¼öÓÃÓÚÖÐÓׯóÒµÖ÷ÌâÉ豸 £¬Í¨¹ý1+1µçÔ´ÈßÓà £¬ÌáÉýÓ²¼þ¿¿µÃסÐÔ £¬Ö§³ÖVSUÐé¹¹»¯¼¼Êõ £¬´ó·ùÌáÉýÍøÂçϵͳµÄ¿¿µÃסÐԺ͸ßЧÐÔ
match2
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

penÎÒÒªÌáÎÊ
È«Êý
À©´ó²Û(1)
¼æÈÝ(1)
ºÏÓó¡¾°(1)
»·Â·¼ì²â(1)
GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S5760-XϵÁÐǧÕ×»¥»»»úÖÐS5760CµÄCÊÇʲôÒâ˼£¿
ÓÐЧ 41 ÎÞÓà 4

ÔÚÐͺÅÃû¶¨Ãû¹æ¶¨ÖÐ £¬Êý×ÖºóÃæ+C´ú±í»¥»»»ú´øÓÐÀ©´ó²Ûλ

GA»Æ½ð¼× 2022Äê07ÔÂ25ÈÕ
RG-S5760-XϵÁл¥»»»úºÏÓÃÓÚʲô³¡¾°ÄØ£¿
ÓÐЧ 36 ÎÞÓà 4

1¡¢800ÈË×óÓÒµÄÖÐÓ×ÐÍÆóÒµÍøÂçÖ÷Ìâ £»
2¡¢ÖÐÓ×ÐÍÆóÒµÔ°ÇøÍø £¬½ÌÓýÍø/³ÇÓòÍø £¬¿í´øÓ×ÇøµÄÍøÂç»ã¾Û £»
3¡¢Êý¾ÝÖÐÐÄ·þÎñÆ÷µÄǧÕ×½ÓÈë¡£

·¢Õ¹È«Êý expend
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ£¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖã¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close ev-close-m
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌ⣿
ev-close ev-close-m
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ£¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close ev-close-m
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£©£¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Ò飿
Ϊ¾¡¿ì½â¾öÎÊÌâ £¬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿