GA»Æ½ð¼×

´Ó³ß¶Èµ½Â䵨£ºÍòÕ×Ô°Çø £¬Ñ¡ÒÔÌ«²Ê¹â Ø­ ¡¶ÍòÕ×Ô°ÇøÒÔÌ«²Ê¹â×êÑл㱨¡·¼¼Êõ×êÑлá
date
Ô¤Ô¼Ö±²¥
AIʱÆÚ £¬Ò½ÁÆÍøÂçÔõô½¨ Ø­ GA»Æ½ð¼×Ò½ÁƼ«¼òÒÔÌ«²Ê¹âË«³¬ÈÚºÏÍøÂç½â¾ö¹æ»®°ä²¼
date
Ô¤Ô¼Ö±²¥
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
²úÆ·
< ·µ»ØÖ÷²Ëµ¥
²úÆ·ÖÐÐÄ
²úÆ·
½â¾ö¹æ»®
< ·µ»ØÖ÷²Ëµ¥
½â¾ö¹æ»®ÖÐÐÄ
ÐÐÒµ
ºÏ×÷ͬ°é
·µ»ØÖ÷²Ëµ¥
Ñ¡ÔñÇøÓò/˵»°
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

Äú¶©ÔĵIJúÆ·ÓиüР£¬Çëʵʱ²éÔÄ

²é¿´ÏêÇé
RG-S12006
RG-S12006
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
¼ÓÔØÖÐ...0%
zoomup
ͼƬ

RG-S12006

RG-S12006

ÀàÐÍ£º

²úÆ·¸öÐÔ£º

µ±¼´Õ÷ѯ

ͳһ»¥»» £¬Èںϴ洢ÓëÒÔÌ«Íø

RG-S12000 Cloud ComputingϵÁÐÃæÏòÏÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÍÆËãµÄ»¥»»»ú²úÆ·Ïß¿ÉΪ·þÎñÆ÷ÌṩFCoE£¨Fibre Channel over Ethernet£©½ÓÈëºÍÒÔÌ«Íø½ÓÈë·þÎñ £¬´Ó¶øÔ®ÊÖÓû§ÇáËÉÕûºÏÒì¹¹µÄ´æ´¢ÍøºÍÊý¾ÝÍø £¬Ï÷¼õÍøÂçÖеÄÉ豸ÊýÁ¿ £¬¼ÈÄÜÕæÕýʵÏÖÊý¾ÝÖÐÐÄÍøÂç¼Ü¹¹µÄÈÚºÏ £¬ÓÖÄܳä·Ö±£»¤Óû§ÒÑÓÐͶ×Ê¡£

¹¹½¨ÎÞ×èÈûÊý¾ÝÖÐÐÄ

RG-S12000 Cloud ComputingϵÁУ¨Ö÷Ì⣩+ RG-S6200ϵÁУ¨ÍòÕ×½ÓÈ룩+RG-S6000£¨Ç§Õ×½ÓÈ룩ϵÁй¹½¨´Ó½ÓÈëµ½Ö÷ÌâÕæÕýÎÞ×èÈûµÄÊý¾ÝÖÐÐÄÍøÂ磨Clos Network £¬·¢Ô´£º±´¶û³¢ÊÔÊÒClosÏÈÉúÉè¼Æ £¬ÓÃÓÚµç»°ÍøÂç £¬ÊµÏÖÎÞ×èÈû»¥»»¡£Clos NetworkµÄÕæÕýÔ¢ÒâÊÇʵÏÖÕûÍøµÄÎÞ×èÈû £¬¶ø·Çµ¥Ò»µÄ»ùÓÚij¸ö²úÆ·µÄÎÞ×èÈû¡££©

RG-S12000 Cloud ComputingϵÁÐÔÚÒµÄÚÂÊÏÈÖ§³Ö40GºÍ100G³ß¶ÈÄ £¿é £¬½«40G/100GÕæÕýÂ䵨 £¬Ô®ÊÖÓû§×é½¨ÃæÏòÔÆÍÆËãµÄÐÂÒ»´úÊý¾ÝÖÐÐÄÎÞ×èÈû»¥»»ÍøÂç¡£

È«ÃæµÄÊý¾ÝÖÐÐÄÐé¹¹»¯¸öÐÔ

Ö§³ÖÒµ½çµ±ÏȵÄVSU2.0Ðé¹¹»¯¼¼Êõ £¬½«¶ą̀ÎïÀíÉ豸Ðé¹¹»¯ÎªÒ»Ì¨Âß¼­É豸 £¬Í³Ò»ÔËÐÐÖÎÀí £¬´ó·ùÏ÷¼õÍøÂç½Úµã £¬½µµÍÍøÂçÔËάÖÎÀíÈËÔ±¹¤×÷Á¿¡£Ôö³¤ÍøÂç¿¿µÃסÐÔ £¬ÊµÏÖ50~200msÁ´Â·¹ÊÕϼ±¾çÇл» £¬±£¾þÇͺ¦ÒµÎñ²»Öжϴ«Êä¡£Ö§³Ö¿çÉ豸Á´Â·¾ÛºÏ £¬·½±ã½ÓÈë·þÎñÆ÷/»¥»»»úʵÏÖË«»îÁ´Â·ÉÏÁª £¬ÍøÂçÓÐЧÏνӴø¿í³É±¶Ôö³¤¡£

GA»Æ½ð¼×ÍøÂ绹¶ÔÒѳÉÊìÀûÓõÄVSUÐé¹¹»¯¼¼Êõ½øÐдó·ù¼¼ÊõÉý¼¶£ºËùÓи߻úÄܽӿÚÏß¿¨É϶¼¼¯³ÉÁËרÓÃVSUÓ²¼þ´¦Öõç· £¬²¢¾ß±¸³ÉÁ¢VSL£¨Virtual Switching Link £¬Ðé¹¹»¥»»Á´Â·£©ÄÜÁ¦ £¬ÌáÉýÓû§Ñ¡ÅäÉ豸½Ã½ÝÐÔ£»VSL×î´óÁ´Â·´ø¿í´ïµ½2.56T £¬¸ß¾ÓÒµ½çµÚÒ» £¬³¹µ×½â³ýÐé¹¹»¥»»³ÉÔ±¼ä´ø¿íÆ¿¾±¡£

Ö§³ÖVRFÐé¹¹»¯¸öÐÔ £¬ÊµÏÖÊý¾ÝÖÐÐÄÍøÂçÒ»±ä¶à £¬±£ÏÕ¶àÒµÎñ°²È«¸ôÀë¡£

Ö§³ÖIEEE802.1Qbg³ß¶È½ç˵µÄVEPA£¨Virtual Ethernet Port Aggregator £¬Ðé¹¹ÒÔÌ«Íø¶Ë¿Ú¾ÛºÏ£© £¬¿ÉÄܽ«·þÎñÆ÷Ðé¹¹»ú²úÉúµÄÊý¾ÝÁ÷Ç£Òýµ½ÎïÀíÍøÂçÉ豸ÉϽøÐГӲ»¥»»” £¬ÈÃÐé¹¹»ú»¥»»Ö°ÄܳÁÐÂ»Ø¹éµ½ÍøÂçÉ豸 £¬¼È½â¾öÁËÐé¹¹»úÁ÷Á¿ÎÞ·¨¼à¹Ü¡¢½Ó¼û½ÚÔìÕ½ÊõÎÞ·¨Í³Ò»²¿ÊðµÈÎÊÌâ £¬ÓÖ½â³ý´«Í³“Èí»¥»»”¶Ô·þÎñÆ÷×ÊÔ´µÄÕ¼Óà £¬Ê¹ÏÂÒ»´úÊý¾ÝÖÐÐÄÍøÂç½â¾ö¹æ»®¸üºÃÊÊÓ¦Ðé¹¹»¯ÍÆËã»·¾³¡£

Ö§³ÖÐé¹¹»ú¸ÐÖª¼°°²È«Õ½Êõ×Ô¶¯Ç¨áã £¬ÓÐЧʵÏÖ´ó¹æÄ£·þÎñÆ÷Ðé¹¹»¯ÀûÓû·¾³ÖÐÐé¹¹»úÁ÷Á¿µÄ°²È«½ÚÔìÕ½Êõͳһ²¿Ê𠣬²¢Í¨¹ýÊý¾ÝÖÐÐÄÍøÂçÖÎÀíÆ½Ì¨¹²Í¬Êý¾ÝÖÐÐÄ»¥»»»ú¡¢Ðé¹¹»úÖÎÀí½ÚÔìÆ½Ì¨ £¬ÊµÏÖÐé¹¹Ö÷»úÈ«ÍøÁìÓòÄÚ×ÔÓÉǨáãʱ¶ÔÓ¦°²È«½ÚÔìÕ½ÊõµÄͬ²½Ç¨áã £¬½â³ý·þÎñÆ÷Ðé¹¹»¯»·¾³ÖÐÍøÂ簲ȫ·ì϶ £¬Ï÷¼õÍøÂçÊØ»¤¹¤×÷Á¿¡£

¹¹½¨TRILLͨÃ÷»¥»»ÍøÂç £¬ÎªÐé¹¹»¯ÔÆÍÆËãµì¶¨»ù´¡

³É³¤ÖеÄÊý¾ÝÖÐÐÄÖÁÉÙÒªÃæ¶ÔÈý¸öÍøÂç·½ÃæµÄÌôÕ½£º¸ü´óµÄ´ø¿í¡¢¸ü½Ã½ÝµÄ×éÍøºÍ¸üµ¥Ò»µÄÖÎÀí¡£IETF×îÐÂÔì¶©µÄTRILL£¨Transparent Interconnection of Lots of Links £¬¶àÁ´½ÓͨÃ÷»¥Áª£©³ß¶ÈºÍ̸ £¬±ãÒ»¾Ù½â¾öÁËÕâÈý¸öÎÊÌâ¡£

TRILLÒýÈëÀàËÆIS-ISµÄ·ÓÉ»úÔì £¬¶þ²ãÊý¾Ý±¨Îİ´×î¶Ìõ辶ת·¢ £¬²¢ÒýÈëTTL½â³ýÍøÂçÄÚ¶þ²ã»·Â· £¬´ó·ùÔö³¤ÍøÂç²»±äÐÔ¡£Êý¾ÝÖÐÐÄÄÚʹÓÃTRILLºÍ̸ʵÏÖ³¬´ó¹æÄ£¶þ²ã×éÍø £¬¿ÉÌáÉýÓû§ÒµÎñ²¿Êð½Ã½ÝÐÔ £¬²¢À©´óÐé¹¹»úǨáãÁìÓò¡£

TRILL×éÍøÏ £¬Ëùº±¼û¾ÝÁ÷Á¿»ùÓÚSPF¼°ECMPʵÏÖ¼±¾çת·¢ £¬½â¾ö´«Í³STPºÍ̸ÖдæÔڵĴÎÓÅõè¾¶ÎÊÌâ £¬²¢ÇÒ²»×èÈûÈκζ˿Ú £¬´ø¿íÀûÓÃÂÊÌáÉýÖÁ100%¡£

Ô̺¬RG-S12000ϵÁÐÔÚÄÚ £¬GA»Æ½ð¼×ÍøÂçÈ«ÏßÐÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÍÆË㻥»»»ú²úÆ·¾ùÓ²¼þоƬ֧³ÖTRILLºÍ̸ £¬È«Ïß²úƷͨ¹ýTRILLºÍ̸ͨѶ £¬¿ÉÓÐЧ¼ò»¯ÍøÂçÉè¼Æ £¬Ìá¸ßÍøÂç¿ÉÀ©´óÐԺ͵¯ÐÔ £¬²¢Îª¹¹½¨Ò»¸ö´óÐ͵ÄÐé¹¹»¯ÔÆÍÆËãÍøÂçµì¶¨»ù´¡¡£

ÂÌÉ«»·±£Éè¼Æ

RG-S12000ϵÁÐÖ§³Ö¶ÔµçÔ´µÄÖÇÄÜÖÎÀíÖ°ÄÜ £¬²¢Ñ¡È¡ÁË ¸ßЧµÄµçԴϵͳ¼Ü¹¹Éè¼Æ£¨DC-DCµçԴת»»Ä £¿é£©ÊµÏָߴï95%µÄµçԴת»»Ð§ÄÜÓÐЧ½ÚÄÜ¡£¶ÀÓеĵçÔ´¼à¿ØÖ°ÄÜ £¬±£ÕÏÓû§¿Éƾ¾ÝÏÖʵʹÓÃÇé¿ö°´Ðè×°ÖõçÔ´£»Äܹ»Ö§³Öµ¥°å°¤´ÎÉϵ磨½µµÍµ¥°åͬʱÉÏµç´øÀ´µÄµçÔ´³å»÷ £¬Ìá¸ßÉ豸ÊÙÃü £¬½µµÍµç´Å·øÉ䣩 £¬Äܹ»½ÚÔìµ¥°åϵç £¬¸ôÀë¹ÊÕÏ/¿ÕÏе¥°å £¬½µµÍϵͳ¹¦ºÄ¡£

ÖÇÄܵçÉÈÉè¼Æ £¬Ñ¡È¡¸ßЧµÄοص÷¿ìµçÉÈ £¬Ö§³ÖÎÞ¼¶µ÷¿ì¡£ÏµÍ³Äܹ»×Ô¶¯ÍøÂçµ¥°åζÈ £¬Æ¾¾ÝÉ豸ÏÖʵÇé¿öÍÆËãµçÉȵ÷¿ìÇúÏß £¬²¢½«µ÷¿ìºÅÁîÏ·¢µ½µçÉÈ¿ò¡£ÏµÍ³Ö§³ÖµçÉÈ״̬¼à¿Ø£¨×ª¿ì¼à¿Ø¡¢¹ÊÕϸ澯µÈ£©Äܹ»Æ¾¾Ý»·¾³Î¶ȡ¢µ¥°åÅäÖÃ×Ô¶¯·ÖÇøµ÷¿ì £¬½µµÍÉ豸¹¦ºÄºÍÔËÐÐÔëÉù £¬ÓÐЧ½µµÍ»·¾³ÔëÒô²¢µ¢¸éµçÉÈÊÙÃü¡£

RG-S12000ϵÁÐÖ§³ÖÄÚ²¿¶Ë¿ÚµÄ×Ô¶¯¼ì²â £¬µ±Ä³²ÛλδÅäÖýӿڰåʱ £¬»òÕß¶Ë¿ÚδÏνÓÏßÀÂʱ³½ £¬ÏµÍ³Äܹ»×Ô¶¯¹Ø¹ØÏàÓ¦µÄÄÚ²¿¶Ë¿Ú £¬½Ú¼óÁËÕû»ú¹¦ºÄ¡£Ñ¡È¡³¬µÍ¹¦ºÄоƬ £¬Êý¾ÝÖÐÐÄ»¥»»»úϵÁл¥»»»úÔÚоƬѡÔñʱ £¬¶àÊýѡȡ65nm¹¤ÒÕÉè¼ÆµÄоƬ £¬Ïà±È´«Í³»¥»»»ú £¬½Ú¼ó20%ÒÔÉϵÄÄܺÄ¡£

µçÐż¶¿¿µÃסÐÔ±£»¤

1. ÎÞµ¥µã¹ÊÕÏÉè¼Æ

ѡȡÎÞÔ´±³°åÔ¤·À»úÏä³öÏÖµ¥µã¹ÊÕÏ£»ËùÓйؼüÆ÷¼þ £¬ÈçÒýÇæ¡¢µçÔ´¡¢µçÉȺÍCrossbarµÈ¾ùѡȡÈßÓàÉè¼Æ£»Ë«ÒýÇæÇл»Ê±ÊµÏÖÍòÕ×Êý¾ÝÒµÎñ²»ÖжÏת·¢ £¬ÓÐЧ±£ÕÏÍøÂç²»±ä¡£ËùÓе¥°åºÍµçÔ´Ä £¿éÖ§³ÖÈȲå°ÎÖ°ÄÜ £¬²¢ÇÒ¶ÔÆäËüµ¥°åÉÏÔËÐеÄÒµÎñÎÞÓ°Ïì¡£

Ö§³ÖµçÔ´ÈßÓà £¬Ö§³ÖÄÚÖÃÈßÓàµçÔ´Ä £¿éºÍÄ £¿é»¯µçÉÈ×é¼þ £¬ËùÓнӿڰå £¬µçÔ´Ä £¿éÒÔ¼°µçÉÈÄ £¿é¾ùÄܹ»ÈȲå°Î¶ø²»Ó°ÏìÉ豸µÄÕý³£ÔËÐС£´Ë±íÕû»ú»¹Ö§³ÖµçÔ´ºÍµçÉȵĹÊÕϼì²â¼°¸æ¾¯ £¬Äܹ»Æ¾¾Ýζȵı䶯×Ô¶¯µ÷½ÚµçÉȵÄת¿ì £¬¸üºÃµÄÊÊÓ¦Êý¾ÝÖÐÐĵĻ·¾³¡£»¹¾ß±¸É豸¼¶ºÍÁ´Â·¼¶µÄ¶à³Á¿¿µÃסÐÔ±£»¤¡£Ñ¡È¡¹ýÁ÷±£»¤¡¢¹ýѹ±£»¤ºÍ¹ýÈȱ£»¤¼¼Êõ¡£

2. µ¯ÐÔÒÔÌ«Íø¼¼Êõ

RG-S12000 Cloud ComputingϵÁÐÖ§³ÖRERP¼¼Êõ£¨¼±¾çÒÔÌ«Íø»·±£»¤ºÍ̸£© £¬ÈÚºÏÁËSDH¹ÊÕÏ×ÔÓúµÄ¸ß¿¿µÃסÐÔÓëÒÔÌ«ÍøµÄ¾­¼ÃÐÔ¡¢¸ß´ø¿íµÅ×ÅÊÆ £¬ÔÚRERPÍøÂçÉÏÀ©´óÖ§³ÖIPv4/IPv6·ÓɺÍ̸¡¢MPLSÖ°ÄÜ £¬Äܹ»±£ÏÕÍòÕ×Ïß¿ìÒµÎñÇé¿öÏÂÓ×ÓÚ50msµÄ¹ÊÕÏÇл»¹¦·ò £¬±£ÕÏÓïÒô¡¢ÊÓÆµµÈʵʱҵÎñ²»ÊÜÍøÂçÊÕÁ²Ó°Ïì¡£

RG-S12000 Cloud ComputingϵÁÐÖ§³ÖREUP¼¼Êõ £¬ÔÚÀ©´óÖ§³ÖIPv4/IPv6·ÓɺÍ̸¡¢MPLSÖ°ÄܵÄÇé¿öÏ £¬±£ÕÏË«Á´Â·ÉÏÁªÍøÂçÍØÆËµÄÒµÎñºÁÃë¼¶¼±¾çÇл»¡£µ±ÍøÂçÉϳÐÔØ¶àÒµÎñ¡¢´óÁ÷Á¿µÄʱ³½Ò²²»Ó°ÏìÍøÂçµÄÊÕÁ²¹¦·ò £¬±£ÕÏÒµÎñµÄÕý³ £·¢Õ¹¡£

3. ·ÓɺÍ̸µÄ¸ß¿¿µÃס±£ÏÕ

RG-S12000 Cloud ComputingϵÁÐÖ§³ÖOSPF/IS-IS/BGPµÄÓÅÑųÁÆô¼¼Êõ£¨Graceful Restart£© £¬ÌṩºÁÃë¼¶µÄÇл»¹¦·ò£»Ö§³ÖECMP/WCMP £¬¿ÉÔ®ÊÖÓû§Ê¹ÓöàÌõÁ´Â· £¬²»½öÔö³¤ÁË´«Êä´ø¿í £¬²¢ÇÒÄܹ»ÎÞʱÑÓÎÞ¶ª°üµØ±¸·ÝʧЧÁ´Â·µÄÊý¾Ý´«Êä £¬ÊµÏÖÁ÷Á¿µÄ¸ºÔØÆ½ºâ¼°ÈßÓ౸·Ý£»Ö§³Ö¶¯Ì¬Â·ÓɺÍ̸¡¢¿ç°å¶Ë¿Ú¾ÛºÏ¡¢Ð鹹·ÓÉÈßÓàºÍ̸£¨VRRP£©µÈ±£»¤»úÔì £¬ÓÐЧ±£ÕÏÈ«Íø¸ß¿ì¿¿µÃסÔËÐС£

È«ÃæµÄIPv6½â¾ö¹æ»®

RG-S12000 Cloud ComputingϵÁÐÏß¿¨É¢²¼Ê½ÊµÏÖIPv6ÒµÎñÓ²¼þ´¦Öà £¬Ö§³ÖÍòÕ×IPv6ÒµÎñÏß¿ìת·¢¡£ È«ÃæÖ§³ÖIPv6ºÍ̸×å¼°±àÖ·½á¹¹ £¬Ö§³ÖND£¨ÁÚ¾Ó·¢ÏÖ£©¡¢ICMPv6¡¢Path MTU Discovery¡¢DNSv6¡¢DHCPv6µÈIPv6¸öÐÔ¡£

RG-S12000 Cloud ComputingϵÁÐÈ«ÃæÖ§³ÖIPv6¾²Ì¬Â·ÓÉ¡¢RIPng¡¢OSPFv3¡¢BGP4+µÈIPv6µ¥²¥Â·ÓɺÍ̸ £¬Ö§³ÖMLD v1/v2¡¢MLD Snooping¡¢PIM-SMv6µÈIPv6×é²¥¸öÐÔ £¬ÎªÓû§ÌṩÃÀÂúµÄIPv4/IPv6½â¾ö¹æ»®¡£

RG-S12000 Cloud ComputingϵÁÐÖ§³Ö·á˶µÄIPv4ÏòIPv6¹ý¶É¼¼Êõ £¬Ô̺¬£ºIPv6ÊÖ¹¤Ëí·¡¢×Ô¶¯Ëí·¡¢6to4Ëí·¡¢ISATAPËí·µÈËí·¼¼Êõ £¬±£ÕÏIPv4ÍøÂçÏòIPv6ÍøÂçµÄ»¬Èó¹ý¶É¡£

RG-S12000 Cloud ComputingϵÁÐÖ§³Ö·á˶µÄIPv6ÖÎÀí¸öÐÔ £¬Ö§³ÖSNMP v6¡¢Ping /Traceroute v6¡¢IPv6 TACACS+/ RADIUS¡¢Telnet/SSH v6¡¢NTP v6 £¬Âú×ã´¿IPv6ÍøÂçÉ豸ÖÎÀíµÄ±ØÒª¡£

IPFIXÁ÷Á¿Í¨Ã÷»¯¹æ»®

RG-S12000 Cloud ComputingϵÁл¥»»»úÔÚÒµÄÚÂÊÏÈÖ§³Ö×îÐÂÒ»´ú¹ú¼ÊÁ÷Á¿¼à¿Ø³ß¶ÈIPFIX£¨IP Flow Information Export£© £¬ÇкϹú¼Ê³ß¶È·¢Õ¹Ç÷Ïò £¬²¢ÏòϼæÈÝNetflow v9¡£IPFIX¶àÒµÎñÄ £¿éѡȡ¸ß»úÄܵÄNPƽ̨ £¬Ö§³ÖÍòÕ×ÒµÎñÁ÷Á¿µÄ¼à¿Ø¡£

½áºÏGA»Æ½ð¼×Á÷Á¿·ÖÎöϵͳ £¬IPFIX¼¼ÊõÄܹ»¶ÔÍøÂçÖеÄËùÓÐÁ÷Á¿½øÐÐͳ¼Æ·ÖÎöºÍÒì³£¼ì²â £¬Êä³ö¸÷Àà·á˶µÄÍøÂçÁ÷Á¿·ÖÎö±¨±í £¬Ô̺¬£ºÁ÷Á¿Ê¹Óñ¨±í¡¢º¹Ç౨±í¡¢½Ó¿Ú±¨±í¡¢¿É½âÎöµÄÖ÷»úµØÖ·¡¢Á÷Á¿·ÖÎö¡¢±äÁ¿ÏÔʾµÈÐÅÏ¢ £¬¿ÉÄÜÔ®ÊÖÖÎÀíÔ±ÔÚÍøÂçÒì³£ÐÐΪ²úÉúʱ¼±¾ç·ÖÎö³öÍøÂçÖдæÔÚµÄÎÊÌâ £¬ÎªÍøÂçÈÝÁ¿¹æ»®¡¢ÍøÂçÀûÓÃ¼à¿ØÒÔ¼°¹ÊÕÏÕï¶ÏµÈÌṩ¿Í¹ÛÕýÈ·µÄ¾ö²ßƾ¾Ý £¬ÊµÏÖÕæÕýµÄÍøÂçÁ÷Á¿¿ÉÊÓ»¯¡£

IPFIX¶àÒµÎñÄ £¿é×÷Ϊ¶ÀÁ¢ÒµÎñ½Ã½ÝÀ©´óµ½GA»Æ½ð¼×»¥»»»úÖÐ £¬Ñ¡È¡¶ÀÁ¢µÄÓ²¼þƽ̨ £¬±£ÕÏÔÚ¶àÒµÎñÄ £¿é½øÐÐÊØ»¤»ò¹ÊÕϵÄÇé¿öÏ £¬Ö÷ÌâÉ豸Êý¾ÝÒµÎñÕý³£×ª·¢ £¬±£ÕÏÁËÖ÷ÌâÉ豸µÄ¸ß¿¿µÃס¡£

ÀûÓÃÊý¾Ý°²È«·À»¤

GA»Æ½ð¼×ÍøÂç·À»ðǽÄ £¿éÊÇÒµÄÚµÚÒ»¿îÕæÕýµÄ³¬ÍòÕ׸߻úÄÜ·À»ðǽÄ £¿é £¬¿ÉÀûÓÃÓÚRG-S12000 Cloud ComputingϵÁл¥»»»ú¡£¼¯³ÉÁË·À»ðǽ¡¢ÀûÓð²È«Óò¡¢Ðé¹¹·À»ðǽºÍNATµØÖ·×ª»»µÈһϵÁÐÖ°ÄÜ £¬½«ÍøÂçÓ밲ȫÉ豸½øÐÐÕæÕýµÄÈÚºÏ £¬ÌáÉýÁËÖ÷Ì⻥»»µÄ°²È«½ÚÔìÄÜÁ¦ £¬ÎªÓû§µÄÒµÎñ½áºÏÆäÍøÂçÌá¹©È«ÃæµÄ°²È«·À»¤¡£

GA»Æ½ð¼×ÍøÂç·À»ðǽÄ £¿éÄÜÌṩ±í²¿¹¥»÷·À±¸¡¢ÄÚÍø°²È«¡¢×´Ì¬¼ì²âµÈÖ°ÄÜÓÐЧµÄ±£ÕÏÍøÂçµÄ°²È«¡£ÊµÊ±¼ì²â¸÷ÀàÍøÂçÒµÎñÏνÓ״̬ £¬²¢ÌṩÓʼþ¸æ¾¯¡¢¹¥»÷ÈÕÖ¾¡¢Á÷ÈÕÖ¾ºÍÍøÂçÖÎÀí¼à¿ØµÈÖ°ÄÜ £¬Ð­ÖúÓû§½øÐÐÍøÂçÖÎÀí¡£Æä²úÆ·Óë»ù´¡ÍøÂçÉ豸ÈÚºÏ £¬ÓµÓм´²å¼´Óá¢À©´óÐÔÇ¿µÄÌØµã £¬½µµÍÁËÓû§ÖÎÀíÄѶÈ £¬Ï÷¼õÁËÊØ»¤³É±¾¡£

RG-S12000 Cloud ComputingϵÁл¥»»»úÖ§³ÖCPP¡¢NFPPµÈ°²È«·ÀÓù¼¼Êõ £¬¿ÉʵÏÖARP¡¢DHCP¡¢ICMP¡¢IPɨÃè¡¢DHCP V6¡¢NDµÈ¸÷À๥»÷µÄ×Ô¶¯·ÀÓù £¬¿É×Ô½ç˵¿¹¹¥»÷µÄ±¨ÎÄÀàÐÍ £¬±£ÕÏÉ豸×ÔÉíÒÔ¼°Õû¸öÍøÂçµÄ°²È«¿¿µÃס¡£

¼¼Êõ²ÎÊý

¼¼Êõ²ÎÊý

²ÎÊýÃèÊö

²úÆ·ÐͺÅ

RG-S12010

RG-S12006

Ä £¿é²å²Û

10¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ £¿é£©

6¸ö£¨2¸öÓÃÓÚÖÎÀíÒýÇæÄ £¿é£©

±³°å´ø¿í

256T

128T

»¥»»ÈÝÁ¿

51.8Tbps/204.8Tbps

27.6Tbps/102.4Tbps

°üת·¢¿ìÂÊ

7680Mpps/48000 Mpps

3840Mpps/24000 Mpps

802.1q VLAN

4K

ÏÂÒ»´úÊý¾ÝÖÐÐÄÓëÔÆÍÆËãÍøÂç¸öÐÔ

¼ÓÇ¿ÒÔÌ«Íø¸öÐÔ£¨DCB£©

802.1Qbb: Priority-based Flow Control (PFC)  £¬»ùÓÚÓÅÏȼ¶µÄÁ÷¿Ø

802.1Qaz: Enhanced Transmission Selection (ETS and DCBX) £¬¼ÓÇ¿´«ÊäÑ¡Ôñ

802.1Qau: Congestion Notification (CN/QCN) £¬ÓµÈû¹«¸æ

ͳһ»¥»»¸öÐÔ£ºFCoE£¨Fibre Channel over Ethernet£©

ÔÆÍÆËãÓëÐé¹¹»¯¸öÐÔ£ºTRILL¡¢VSU¡¢VEPA¡¢802.1Qbg

L2ºÍ̸

IEEE802.3£¨10Base-T£©¡¢IEEE802.3u£¨100Base-T£©¡¢IEEE802.3z£¨1000Base-X£© ¡¢IEEE802.3ab£¨1000Base-T£©¡¢IEEE802.3ae£¨10GBase£©¡¢IEEE802.3ba£¨40G/100G£©¡¢IEEE802.3ak¡¢IEEE802.3an ¡¢IEEE802.3X¡¢IEEE802.3ad£¨Á´Â·¾ÛºÏ £¬Í¬Ê±Ö§³Ö¿ç°åÁ´Â·¾ÛºÏ£©¡¢IEEE802.1P¡¢IEEE802.1X¡¢IEEE802.1Q¡¢IEEE802.1D£¨STP£©¡¢IEEE802.1w£¨RSTP£©¡¢IEEE802.1s£¨MSTP£©¡¢IGMP Snooping ¡¢Jumbo Frame¡¢IEEE802.1ad£¨QinQ¡¢½Ã½ÝQinQ£©¡¢GVRP

L3ºÍ̸(IPV4)

Ö§³ÖBGP4¡¢IS-IS¡¢OSPFv2¡¢RIPv1¡¢RIPv2¡¢MBGPµÈµ¥²¥Â·ÓɺÍ̸¡¢Route-policy¡¢ECMP¡¢WCMP¡¢VRRP¡¢Ö§³Ö×é²¥IGMP v1/v2/v3¡¢PIM-SSM/SM/DM

IPv6»ù´¡ºÍ̸

ND¡¢ICMPv6¡¢Path MTU Discovery¡¢DNSv6¡¢DHCPv6¡¢ICMPv6¡¢ICMPv6³Á¶¨Ïò¡¢ACLv6¡¢TCP/UDP for IPv6¡¢SNMP v6¡¢Ping /Traceroute v6¡¢IPv6 TACACS+/ RADIUS¡¢Telnet/SSH v6¡¢FTP/TFTP v6¡¢NTP v6¡¢IPv6 MIB support for SNMP¡¢VRRP for IPv6¡¢IPv6 QoS

IPv6·ÓɸöÐÔ

¾²Ì¬Â·ÓÉ¡¢µÈ¼Û·ÓÉ¡¢Õ½Êõ·ÓÉ¡¢OSPFv3¡¢RIPng¡¢BGP4+¡¢MLDv1/v2¡¢PIM-SMv6

IPv6Ëí·¼¼Êõ

ÊÖ¹¤Ëí·¡¢×Ô¶¯Ëí·¡¢ISATAPËí·µÈ

MPLS VPN

¶þ¡¢Èý²ãMPLS VPN¡¢Ö§³Ö MPLS VPN¿çÓò¡¢Ö§³Ö×é²¥VPN

QoS

Ö§³ÖIP Precedence¡¢802.1P¡¢DSCP¡¢TOSµÈEXPÓÅÏȼ¶Ó³Éä £¬Ö§³ÖACLÁ÷·ÖÀà £¬Ö§³ÖÓÅÏȼ¶ÏóÕ÷Mark/Remark £¬Ö§³ÖSP¡¢RR¡¢WRR¡¢DRR¡¢SP+WRR¡¢SP+DRR¡¢WFQµÈ¶àÖÖ¶ÓÁе÷¶È»úÔì £¬Ö§³ÖWRED¡¢REDÓµÈûÔ¤·À £¬Ö§³ÖCAR¡¢LR£¨In/Out£©Á÷Á¿ÕûÐÎÖ°ÄÜ¡¢HOL £¬Ö§³ÖVoQ

¸ß¿¿µÃסÉè¼Æ

Ö§³ÖVSU¡¢Ö§³ÖGR for ISIS/BGP/OSPFµÈ·ÓɺÍ̸¡¢Ö§³ÖISSU¡¢Ö§³ÖRERP¡¢Ö§³ÖREUP¡¢Ö§³ÖRLDP¡¢Ö§³ÖTPP

Ö§³ÖË«ÒýÇæÈȱ¸¡¢Ö§³ÖµçÔ´1+1ÈßÓ౸·Ý¡¢Ñ¡È¡ÎÞÔ´±³°åÉè¼Æ¡¢µçÉÈѡȡÈßÓàÉè¼Æ¡¢ËùÓÐÏß¿¨Ä £¿éºÍµçÔ´Ä £¿éÖ§³ÖÈȲå°ÎÖ°ÄÜ¡¢Ö§³Ö»¥»»¾ØÕóÈßÓ౸·Ý¸ß¿¿µÃסÉè¼Æ

רҵ°²È«¼¼Êõ

NFPP¡¢CPP¡¢·ÀDDOS¹¥»÷¡¢·¸·¨Êý¾Ý°ü¼ì²â¡¢Êý¾Ý¼ÓÃÜ¡¢·ÀÔ´IPºýŪ¡¢·ÀIPɨÃè £¬Ö§³Ö³ß¶ÈºÍÀ©´óACL ¡¢Ö§³ÖIngress/Egress ACL¡¢Ö§³ÖVLAN ACL¡¢Ö§³ÖÈ«¾Ö ACL £¬Ö§³ÖOSPF¡¢RIPv2 ¼°BGPv4 ±¨ÎĵÄÃ÷Îļ°MD5ÃÜÎÄÈÏÖ¤¡¢Ö§³ÖÊÜÏÞµÄIPµØÖ·µÄTelnetµÄµÇ¼ºÍ¿ÚÁî»úÔì¡¢uRPF¡¢Ö§³Ö¹ã²¥±¨ÎÄÒÖÔì¡¢DHCP Snooping £¬Ö§³ÖRADIUS/TACACS+

ÖÎÀí·½Ê½

Ö§³ÖSyslogϵͳ¹¤×÷ÈÕÖ¾ £¬Ö§³Ö¹ÊÕϺ󱨾¯ºÍ×Ô¸´Ô­¡¢Ö§³ÖUSB¡¢Ö§³ÖSNTP¡¢NTPʱÖÓ¡¢Ö§³ÖRMON £¬Ö§³Ö1¡¢2¡¢3¡¢9×é £¬Ö§³ÖSNMP v1/v2/v3c £¬Ö§³ÖConsole/AUX Modem/Telnet/SSH2.0 ºÅÁîÐÐÅäÖà £¬Ö§³ÖFTP¡¢TFTP¡¢Xmodem¡¢Ö§³ÖSPAN/RSPAN/ERSPAN £¬Ö§³ÖIPFIXÁ÷Á¿·ÖÎö

PoE¹©µç

Ö§³ÖPoE¹©µçÖ°ÄÜ £¬¿ÉÅäÖÃPoEÏß¿¨ £¬ÊµÏÖÎÞÏß½ÓÈë¡¢ÊÓÆµ¼à¿Ø¡¢×Ô¶¯½ÚÔìϵͳ¡¢ÎÞÏßÉ䯵¼ø±ðϵͳRFIDµÈ¶àÒµÎñÀûÓÃÖն˵ÄÒÔÌ«Íø¹©µç

ÆäËüºÍ̸

DHCP Client¡¢DHCP Relay¡¢DHCP Server¡¢DNS Client¡¢UDP relay¡¢ARP Proxy¡¢Domain¡¢VPN¡¢Syslog¡¢IPFIX

³ß´ç£¨¿íxÉîx¸ß£©(mm)

437 x 450 x 930.65 £¬¸ß¶È21U

437 x 500 x 486.15 £¬¸ß¶È11U

µçÔ´

RG-PA1200I£º90V~176V £¬¹¦ÂÊ£º530W£»176V~264V £¬¹¦ÂÊ£º1400W

RG-PA2000I£º90V~176V £¬¹¦ÂÊ£º1080W£»176V~264V £¬¹¦ÂÊ£º2000W

MTBF

> 200,000 Ó×ʱ

ζÈ

¹¤×÷ζȣº0¡æ  µ½ 50¡æ

´æ´¢Î¶ȣº-40¡æ µ½ 70¡æ

ʪ¶È

¹¤×÷ʪ¶È£º10% µ½ 90% RH

´æ´¢Êª¶È£º10% µ½ 90% RH

 

·¢Õ¹¾ßÌå²ÎÊý

ÀûÓó¡¾°

prev
next

×ÊÔ´ÖÐÐÄ

ÓªÏú×ÊÁÏ
ÀûÓð¸Àý
¼¼Êõ²©ÎÄ
ÊÛºóÎĵµ

³£¼ûÎÊÌâ

faq-none
ÔÝÎÞÎÊÌâ £¬ÎÒÒªÌáÎÊ
ÈôÊÇÄú±ØÒª¸ü¶à²úÆ·¼¼ÊõÕ÷ѯ
¾ßÌå»úÄÜÄÜ·ñÂú×ãÄúµÄÒµÎñ·åÖµ £¿ÈôºÎ¹æ»®²¿ÊðÓëÅäÖà £¿
msgµ±¼´Õ÷ѯ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾

·µ»Ø¶¥²¿

ÊÕÆð
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµAI¸±ÊÖ
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾ ÎĵµÆÀ¼Û
ev-close ev-close-m
¸Ã×ÊÁÏÊÇ·ñ½â¾öÁËÄúµÄÎÊÌâ £¿
ev-close ev-close-m
Äú¶Ôµ±Ç°Ò³ÃæµÄÖÐÒâ¶ÈÈôºÎ £¿
²»Õ¦µÎ
¼«¶ÈºÃ
dark-star dark-star dark-star dark-star dark-star
ev-close ev-close-m
ÄúÖÐÒâµÄÔ­ÒòÊÇ£¨¶àÑ¡£© £¿
Äú¶ÔÎĵµÊÇ·ñ»¹ÓÐÆäËüµÄÎÊÌâ»ò½¨Òé £¿
Ϊ¾¡¿ì½â¾öÎÊÌâ £¬ÇëÄúÁôÏÂÁªÏµ·½Ê½Òﱋȯ¸´
ÓÊÏä
ÊÖ»úºÅ
ev-bg
¸Ð¼¤ÄúµÄ·´À¡£¡
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
GA»Æ½ð¼×¡¤(Öйú¼¯ÍÅ)¹Ù·½ÍøÕ¾
ÇëÑ¡Ôñ·þÎñÏîÄ¿
¹Ø¹ØÕ÷ѯҳ
ÊÛǰÕ÷ѯ ÊÛǰÕ÷ѯ
ÊÛǰÕ÷ѯ
ÊÛºó·þÎñ ÊÛºó·þÎñ
ÊÛºó·þÎñ
¶¨¼û·´À¡ ¶¨¼û·´À¡
¶¨¼û·´À¡
¸ü¶àÁªÏµ·½Ê½
¡¾ÍøÕ¾µØÍ¼¡¿