ÄÜÂú×㰲Ȼ³ÇÊÓ×¢ÖÇÄܽ»Í¨¡¢ÊÒ±í¼à¿ØºÍÆäËû¶ñÁÓ»·¾³ÖеIJ¿ÊðÒªÇó
²úÆ·¸öÐÔ£º
¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡¢²»±äµÄÉ豸»úÄÜ
¸ßÆ·ÖÊÓ²¼þÉè¼Æ¡£×ñѹ¤Òµ¼¶Éè¼Æ¹æ·¶£¬Ñ¡È¡¹ú¼Ê´ó³§Ö÷Á÷³ÉÊ칤ҵ¼¶Ð¾Æ¬¡¢¸ß»úÄܹ¤Òµ¼¶ CPU¡¢¹¤Òµ¼¶µçÔ´Ä£¿éºÍÂÁºÏ½ð±í¿Ç£¬±£ÕϲúÆ·µÄ¹¤Òµ¼¶Æ·ÖÊ¡£
ѡȡÎÞµçÉÈÉ¢Èȵç·Éè¼Æ¡¢Ö§³Ö-40~85ºC¹¤×÷»·¾³Î¶ȡ¢IP40 ·À»¤µÈ¼¶¡¢·ÀÀ×µçѹ>=8KV¡¢·ÀÕñ¶¯±£»¤µçÔ´Éè¼Æ¡¢µç´Å×ÌÈÅËļ¶³ß¶È¡¢Äͳå»÷ºÍÕñ¶¯£¬É豸¼´±ãÔÚ¶ñÁÓ»·¾³ÖÐÒ²Äܲ»±ä¿¿µÃסµÄÔËÐС£
Ðé¹¹»¯¼¼Êõ
Ö§³ÖVSU£¨Virtual Switch Unit£©¼´Ðé¹¹»¥»»µ¥Ôª¼¼Êõ¡£Í¨¹ý¾ÛºÏÁ´Â·Ïνӣ¬×î¶à¿É½«8̨ÎïÀíÉ豸Ð鹹Ϊһ̨Âß¼ÉÏͳһµÄÉ豸£¬Ê¹Æä¿ÉÄÜʵÏÖͳһµÄÔËÐУ¬ÀûÓõ¥Ò»IPµØÖ·¡¢µ¥Ò»Telnet¹ý³Ì¡¢µ¥Ò»ºÅÁîÐнӿÚ(CLI)¡¢×Ô¶¯°æ±¾²é³¡¢×Ô¶¯ÅäÖõȸöÐÔ¼ò»¯ÁËÖÎÀí¡£
·á˶µÄÍøÂçÖ°ÄÜÓ밲ȫ¸öÐÔ
Ö§³ÖVLAN¡¢STP/RSTP ¡¢ERPS¡¢×é²¥¡¢¶Ë¿Ú¾µÏñ¡¢QoS¡¢¶Ë¿Ú°²È«¡¢¹ã²¥·ç±©ÒÖÔìµÈ¶þ²ã¸öÐÔ£»Ö§³Ö¾²Ì¬Â·ÓɵÈÈý²ãÍøÂçºÍ̸¡£
ͨ¹ý¶àÖÖÄÚºµÄ°²È«»úÔì¿ÉÓÐЧԤ·ÀºÍ½ÚÔ첡¶¾´«²¼ºÍÍøÂçÁ÷Á¿¹¥»÷£¬½ÚÔì·¸·¨Óû§Ê¹ÓÃÍøÂ磬±£ÕϺϷ¨Óû§ºÏÀí»¯Ê¹ÓÃÍøÂ磬Èç¶Ë¿Ú¾²Ì¬ºÍ¶¯Ì¬µÄ°²È«°ó¶¨¡¢¶Ë¿Ú¸ôÀë¡¢¶àÖÖÀàÐ͵ÄÓ²¼þACL½ÚÔì¡¢»ùÓÚÊý¾ÝÁ÷µÄ´ø¿íÏÞ¿ì¡¢Óû§½ÓÈë½ÚÔìµÄ¶àÔªËØ°ó¶¨µÈ£¬Âú×ãÄúÍøÂç¶ÔÉ豸½ÓÈëµÄ°²È«½ÚÔì¡£
»ù´¡ÍøÂç±£»¤£¨NFPP£©Í¨¹ý½«±¨ÎÄ·ÖÀàÏ޿죨ÖÎÀíÀࡢת·¢Àà¡¢ºÍ̸Àࣩ£¬²¢¶Ô±¨ÎĽøÐй¥»÷¼à²â£¬Ë«³Á±£ÏÕ±£»¤CPUºÍÐÅ·´ø¿í×ÊÔ´ÃâÊܹ¥»÷¸ÉÈÅ£¬±£Õϱ¨ÎĵÄÕý³£×ª·¢ÒÔ¼°ºÍ̸״̬µÄÕý³££¬ÊØ»¤ÍøÂçµÄ²»±ä¡£
½Ã½ÝµÄ×éÍø£¬¼òÒ×µÄÖÎÀí
Ö§³Ö´«Í³µÄÐÇÐÎ×éÍøÄ£Ê½¡¢Í¬Ê±Ò²Ö§³ÖÒÔÌ«Íø¶à»·±£»¤¼¼Êõ£¨ERPS£©ÊµÏÖ»·Ðη½Ê½×éÍø£¬¸Ã×éÍø·½Ê½ÓµÓкܸߵÄÈßÓà¿¿µÃסÐÔ£¬Ò»µ©»·Â·ÓÐÒ»½Úµã³öÏÖ¹ÊÕÏ£¬Äܹ»´ÓÁíÒ»¶Ë½øÐÐÊý¾Ýת·¢£¬Çл»¹¦·ò≤20ms¡£Óë´Ëͬʱ£¬»·Íø·½Ê½Ïà±ÈÐÇÐÎ×éÍø¸ü½Ú¼ó¹âÏË£¬¿ÉÒÔΪÄú½Ú¼ó¿Ï¶¨µÄ½¨Éè³É±¾¡£
ѡȡ½Ã½ÝµÄǧÕ×µç¿Ú+¹â¿Ú£¨·Ç¸´Ó㩵Ĵó¾Ö£¬·½±ãÓû§Æ¾¾ÝÍøÂç¼Ü¹¹½Ã½ÝÑ¡ÔñÏνӴó¾Ö¡£
ͬʱ֧³ÖʹÓô«Í³CLIºÅÁîÐз½Ê½ºÍWebͼÐλ¯½çÃæ·½Ê½ÅäÖû¥»»»ú£¬ÎÞÐèÏàʶ¸´ÔӵĺÅÁîÐкÍÖÕ¶Ë·ÂÕÕ·¨Ê½£¬ÔÊÐíµ¥Ò»¡¢¼±¾çµÄÅäÖû¥»»»ú£¬´Ó¶ø½µµÍ²¿ÊðÄѶȡ£
Syslog·½±ã¸÷ÀàÈÕÖ¾ÐÅÏ¢µÄÍ³Ò»ÍøÂç¡¢ÊØ»¤¡¢·ÖÎö¡¢¹ÊÕ϶¨Î»¡¢±¸·Ý£¬±ãÓÚÖÎÀíÔ±½øÐÐÍøÂçÊØ»¤ºÍÖÎÀí¡£
|
²úÆ·ÐͺŠ|
RG-IS2712G RG-IS2712G-DC |
RG-IS2706G |
|
|
¹Ì»¯¶Ë¿Ú |
8¸ö10/100/1000M µç¿Ú£»4¸ö1000BASE-X SFP¹â¿Ú |
4¸ö10/100/1000M µç¿Ú£»2¸ö1000BASE-X SFP¹â¿Ú |
|
|
À©´óÄ£¿é |
ÎÞ |
||
|
ÖÎÀí¿Ú |
1¸öConsole ¶Ë¿Ú |
||
|
Ò»¼ü³ÁÆô |
Ö§³ÖÒ»¼ü³ÁÆô |
||
|
»¥»»ÈÝÁ¿ |
128G |
||
|
°üת·¢¿ìÂÊ |
26.7Mpps |
13.4Mpps |
|
|
802.1q VLAN |
4K |
||
|
¹¤×÷»·¾³ |
¹¤×÷ζÈ-40¡«85¡æ |
||
|
¹¤×÷ʪ¶È5¡«95%RH |
|||
|
·À»¤µÈ¼¶IP40 |
|||
|
¶Ë¿Ú·ÀÀ×≥8KV |
|||
|
¾ùÔÈÎÞ¹ÊÕϹ¦·ò£¨MTBF£©£º30ÄêÒÔÉÏ |
|||
|
µç´Å×ÌÈÅ |
ESD (IEC 61000-4-2) Level 4 (8K/15K) RS (IEC 61000-4-3) Level 3 (10V/m) EFT (IEC 61000-4-4) Level 3 (1V/2V) CS (IEC 61000-4-6) Level 3 (10V/m) PFMF (IEC 61000-4-8) Level4£¨30A/m£© Surge (IEC 61000-4-5) Level 4+(6KV/2KV) DIP (IEC 61000-4-11) Level3 (10V) |
||
|
L2ºÍ̸ |
G.8032 (ERPS)¡¢IEEE802.3¡¢IEEE802.3u¡¢IEEE802.3z ¡¢IEEE802.3x¡¢IEEE802.3ad¡¢IEEE802.1p¡¢ IEEE802.1x¡¢IEEE802.3ab¡¢IEEE802.1Q¡¢IEEE802.1d¡¢IEEE802.1w¡¢IEEE802.1s¡¢ IGMP Snooping v1/v2/v3 |
||
|
ACL |
³ß¶ÈIP ACL£¨»ùÓÚIPµØÖ·µÄÓ²¼þACL£© À©´óIP ACL£¨»ùÓÚIPµØÖ·¡¢TCP/UDP¶Ë±êÓïµÄÓ²¼þACL£© MACÀ©´óACL£¨»ùÓÚÔ´MACµØÖ·¡¢Ö÷ÕÅMACµØÖ·ºÍ¿ÉÑ¡µÄÒÔÌ«ÍøÀàÐ͵ÄÓ²¼þACL£©»ùÓÚ¹¦·òACL ר¼Ò¼¶ACL £¨¿Éͬʱ»ùÓÚVLANºÅ¡¢ÒÔÌ«ÍøÀàÐÍ¡¢MACµØÖ·¡¢IPµØÖ·¡¢TCP/UDP¶Ë±êÓï¡¢ºÍ̸ÀàÐÍ¡¢¹¦·òµÈ½Ã½Ý×éºÏµÄÓ²¼þACL£© |
||
|
IPv6 ACL&QoS |
Ö§³Ö»ùÓÚÔ´/Ö÷ÕÅIPv6µØÖ·¡¢Ô´/Ö÷ÕŶ˿ڵÄIPv6 ACLºÍIPv6 QoS ÓÅÏȼ¶¶ÓÁÐ:8 |
||
|
°²È«¸öÐÔ |
Ö§³ÖIP¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨ Ö§³ÖIPv6¡¢MAC¡¢¶Ë¿ÚÈýÔªËØ°ó¶¨ ¹ýÂË·¸·¨µÄMACµØÖ· Ö§³Ö»ùÓڶ˿ںÍMACµÄ802.1x Ö§³ÖWEBÈÏÖ¤£¬ºÍ802.1X¡¢ARP-Check¡¢ACL¿Éͬʱ¿ªÆô Ö§³ÖARP-Check Ö§³ÖDAI Ö§³ÖARP±¨ÎÄÏÞ¿ì Ö§³Ö¹ã²¥·ç±©ÒÖÔì ÖÎÀíÔ±·Ö¼¶ÖÎÀíºÍ¿ÚÁî±£»¤ É豸µÇ½ÖÎÀíµÄAAA°²È«ÈÏÖ¤£¨IPv4/IPv6£© Ö§³ÖSSH Ö§³ÖBPDU Guard Ö§³ÖDOS¹¥»÷·À»¤¡¢ARP¹¥»÷·À»¤¡¢ICMP¹¥»÷·À»¤ Ö§³Ö¶Ë¿Ú¸ôÀë¡¢¶Ë¿Ú°²È« Ö§³Ö±¨¾¯¶Ë¿ÚÖ°ÄÜ |
||
|
IP·ÓÉ |
Ö§³Öȱʡ·ÓÉ£¬Ö§³ÖÖ÷»ú¼°Ö±Á¬Íø¶ÎµÄ¾²Ì¬Â·ÓÉ |
||
|
IPv6ºÍ̸ |
IPv6±àÖ·¡¢ÁÚ¾Ó·¢ÏÖºÍ̸£¨ND£©¡¢ICMPv6¡¢IPv6 Ping¡¢IPv6 TracertµÈ |
||
|
ÖÎÀí¸öÐÔ |
SNMPv1/v2c/v3¡¢CLI(Telnet/Console)¡¢RMON(1£¬2£¬3£¬9)¡¢SSH¡¢Syslog¡¢NTP/SNTP¡¢Web |
||
|
»úе½á¹¹ |
³ß´ç£º52*115*160mm (W×H×D) |
||
|
×°Ö÷½Ê½: DIN¿¨¹ìʽ»ò±Ú¹Òʽ |
|||
|
µçÔ´ |
»¥»»£¨AC£©ÊäÈ룺 ¶î¶¨µçѹÁìÓò£º100-240V~ ×î´óµçѹÁìÓò£º90-264V~ ƵÂÊ£º50-60Hz ¶î¶¨µçÁ÷£º0.4A
¸ßѹֱÁ÷£¨HVDC£©ÊäÈ룺 ¶î¶¨µçѹÁìÓò£º140-340VDC ×î´óµçѹÁìÓò£º130-370VDC ¶î¶¨µçÁ÷£º0.4A
Ö±Á÷£¨DC£©ÊäÈ룺 24DCW£¨18-72VDC£©&48DCW£¨18-72VDC£© Ë«ÈßÓàÊäÈë |
||
|
¹¦ºÄ |
Õû»ú¹¦ºÄ≤11.5W |
Õû»ú¹¦ºÄ≤8W |
|
|
É¢ÈÈ |
ÎÞµçÉÈÉè¼Æ£¬¸ßЧɢÈÈÆ¬É¢ÈÈ |
||
Êǵģ¬¸Ã¿î»¥»»»úΪÎÒ˾¹¤Òµ»¥»»»ú¡£¹¤Òµ»¥»»»ú¶¼ÊÇ¿íÎÂÉè¼ÆµÄ¡£